background image

 

REGULATIONS AND APPROVALS

 

Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for 
Spraying Systems Co.

®

 equipment will be voided if instructions for installation, operation, and service are not followed. 

All phases of equipment installation must comply with federal, state, and local codes.  

 

PERSONAL PROTECTIVE EQUIPMENT

 

Spraying Systems Co.

®

 strongly recommends the use of appropriate safety equipment when working in potentially haz-

ardous environments and chemicals. This safety equipment includes, but is not limited to, the following:

 

• 

Protective hat

 

• 

Safety glasses or face shield

 

• 

Chemical

-

resistant safety gloves and apron

 

• 

Long sleeve shirt and long pants

 

Users of this product should never place themselves in the path of the spray. Users should consult and follow the rec-
ommendations of the Safety Data Sheet (SDS) of any chemical or fluid sprayed using this system.

 

PRESSURIZED SYSTEMS 

 

It is important to recognize proper safety precautions when using a pressurized spray system. When dealing with pres-
sure applications, the system pressure should never exceed the lowest rated component. Always know your system, 
all component capabilities, maximum pressures and flow rates. 

 

WARNING: Fluids under pressure can penetrate skin and cause severe injury. 

 

ATTENTION: Always remember to carefully read the chemical manufacturer

s labels, follow SDS and 

all directions.

 

WARNING OF SHOCK HAZARD

 

To reduce the risk of electric shock, do not open the cover on electrical control panel. For service contact            
Spraying Systems Co.

® 

at 1

-

866

-

321

-

2250. 

 

WARNING: Plug panels into a GFCI outlet. 

 

WARNING: To prevent injury, avoid contact with potentially hot parts. Components can cause 
severe burns. Do not aim the spray at any person or part of the body. Do not place any part of your 
body into the spray pattern.

 

USE OF CHEMICAL COMPONENTS

 

Spraying Systems Co. does not manufacture or supply any of the chemical components used in this equipment and is 
not responsible for their effects. Because of the large number of chemicals that could be used and their different 
chemical reactions, the buyer and user of this equipment should determine compatibility of the materials used and 
any of the potential hazards involved.

 

2.2 UNPACKING THE SYSTEM  

The system components come packaged to protect them from damage. Use caution when opening the crate. The 
crate will contain all parts needed to install the unit. Parts of the unit may be wrapped in bubble wrap. Remove all of 
the packaging material wrapping the system. Once unpacked and removed from the crate, the system is ready for  
installation and connection.

 

CAUTION: The packaging may contain exposed cables, hoses, or other components. Always exercise 
caution when opening boxes to avoid accidental damage or slicing of various components.

 

 

Содержание AutoJet VC10

Страница 1: ...AutoJet VC10 Industrial Heated Spray System OWNER S MANUAL ML00VC10HTSYS spray com...

Страница 2: ...ning Control System Options 6 3 7 Spray Control Panel Options 7 4 Installing the System 8 4 1 Filling the Heating Loop 8 4 2 Process Fluid Delivery 9 4 3 Agitator And FRL Unit 10 5 System Start Up and...

Страница 3: ...r environment can be damaged or be in danger if the instructions are not followed correctly ATTENTION Supplementary information for the user that draws attention to possible problems SECTION 2 SAFETY...

Страница 4: ...ATTENTION Always remember to carefully read the chemical manufacturer s labels follow SDS and all directions WARNING OF SHOCK HAZARD To reduce the risk of electric shock do not open the cover on elect...

Страница 5: ...uminated Power On and Power off power pushbuttons and various illuminated selector switches A lockout disconnect switch is mounted on the door A low level indicator is illuminated when the tank is low...

Страница 6: ...tinuous liquid level sensor with auto refill addition Liquid outlet unit with manual 3 way ball valve for tank draining and 2 way ball valve for direct fluid line shut off Air motor driven liquid agit...

Страница 7: ...hes Terminal strips Cord grips for cable entry Figure 3 Digital Zone Control Optional Digital 8 zone control panel with or without timing control which includes the following components mounted into a...

Страница 8: ...the system Note that all the conditioning lines from the pump through all jacketed components and back to the return reservoir must be run in series Never split the flow path as this could result in c...

Страница 9: ...ponent including the ball valves mounted on the tanks are jacketed to maintain consistent heating The hose delivering the fluid from the tank to the nozzles is completely jacketed 2 Finally the nozzle...

Страница 10: ...es down to 5 microns in size CAUTION The agitator should never be operated without an oiled air supply Running without oiled air can result in a mechanical failure Providing more pressure to the agita...

Страница 11: ...ff 9 Open your valve on the air inlet to be in line with the regulator set your pressure regulator to the desired spray pressure and the tank will begin filling 10 Begin supplying air to your agitator...

Страница 12: ...3 SEQUENCE OF OPERATIONS General Information 1 Disconnect turned on 2 Operator powers system on 3 Operator opens air vents on the heating loop 4 Operator fills system with conditioning fluid water 5 O...

Страница 13: ...for liquid pressure tank Auto refill control box air operated Continuous liquid level sensor low level indicator for auto refill timer control box AUTO REFILL PROCEDURE 1 Connect power to the control...

Страница 14: ...e fluid level reaches 10 mm from the bottom of the probe 0 full the Low Tank Level indicator will turn on This is intended as a warning that the system is not automatically refilling The Low Tank Leve...

Страница 15: ...on procedures Pneumatic Connections Check all pneumatic connections for leaks and tighten Check system main air pressure as specified Tighten all screw terminal connections to insure proper bonding Ch...

Страница 16: ...switch to the ON position provide air to the auto refill pump to begin filling C When complete turn the auto refill switch to the OFF position to stop pumping D Repeat this process with appropriate f...

Страница 17: ...nector system should run No lights present insufficient water in the heating jacket loop or damaged sensor d Heater faulty or maximum temperature exceeded Press the EZ button on the heat controller to...

Страница 18: ...ion or design Other company and product names may be trademarks of their respective companies Warranty is one 1 year on non wear parts from ship date Wear items are covered for manufacturing defect on...

Отзывы: