Combi 05-12-25

DESCRIPTION OF THE LUMINAIRE

Please refer to the pictures on page 2:

① 

  Suspension yoke

  Accessory guides 

  Safety screen

  Accessory locking spring

⑤ 

Handle for tilt regulation

⑥ 

Lamp lid opening knob

⑦ 

Carriage with lamp socket

⑧ 

Retaining spring for lamp holder pan

⑨ 

Lamp position adjustment knob

⑩ 

Handle for moving luminaire and for safety cable 
anchorage

INTRODUCTION

The luminaire you have bought complies to 

2006/95/EC, 

2004/108/EC and 2011/65/EU European Directives

The label on the side of the luminaire lists the following 
information:
• model
• mains supply voltage (V)
• lamp wattage (W)
• protection index IP
• maximum allowed ambient temperature in °C
• maximum temperature of the body in °C 
• minimum distance from flammable surface
• information to find the position 0° of the luminaire: 

when the tip of the arrow points upwards 

• maximum tilt angle range. These limits, imposed by 

the lamp manufacturer, should not be exceeded as 
they would reduce the luminaire’s useful life or lead 
to its deterioration.

INSTALLATION

• The luminaire can be either suspended or mounted on 

a stand.

• Do not install the luminaire close to, or in contact 

with flammable surfaces

• The minimum distance at which the luminaire must 

be kept from easily inflammable surfaces is indicated 
on the label.

• The safety norms estimate that a metal wire 

screen be mounted on the front of the luminaire to 
prevent any large glass fragments from falling if the 
projector breaks.

• Remember to connect the safety cable, if required by 

local health and safety regulations

ACCESSORIES: 

the accessories estimated for this projector 

are listed in the products catalogue and can be mounted 
by inserting them in the relevant guides 

② 

so that the 

retaining spring is released 

Colour changers and lens flaps must be bond by the 
safety cable to the luminaire.

ELECTRICAL CONNECTIONS

The luminaire is designed to operate with a 220V to 
240V supply, 50-60Hz.
The power cable conforms to CEI regulations 20-22. 
Before and during the installation, make sure you follow 
the guidelines below:
• Always check the earth wiring for the line being used.
• Ensure the voltage for the unit is the same as the one 

used for the supply

• All units are designed for indoor use: if they have 

to be used outdoors, ensure they are protected from 
dampness and rain.

• Do not use lamps which are different from the ones 

listed in the lamp table

• There are no fuses inside the units, if it is necessary  

they should be installed in the mains

• This model 

can be connected to a dimmer.

WARNING: replace immediately the lamp 
when visibly damaged.

WARNING: The luminaires must always be 

earthed

5

Содержание COM 05 F

Страница 1: ...Manuale utente User manual COM 05 PC COM 05 F COM 12 PC COM 12 F COM 25 PC COM 25 F combi...

Страница 2: ...sent instructions carefully Spotlight srl will not be responsible for damage resulting from instructions not being followed 2 ACHTUNG Vor Inbetriebnahme zuerst die folgenden Anweisungen sorgf ltig les...

Страница 3: ...ccorre tenere il faro da superfici infiammabili indicata nella targhetta Le norme di sicurezza prevedono che davanti alla lente sia posta una rete metallica per evitare la caduta di eventuali grossi f...

Страница 4: ...icare la sua inclinazione Lo stesso si pu fare riguardo alla rotazione dell asse verticale facendolo ruotare sul perno di aggancio al traliccio Ruotando il pomello si fa avanzare e retrocedere la slit...

Страница 5: ...be kept from easily inflammable surfaces is indicated on the label The safety norms estimate that a metal wire screen be mounted on the front of the luminaire to prevent any large glass fragments fro...

Страница 6: ...n a certain position and thus change its inclination You can rotate the luminaire on the vertical axis by rotating it on its hook clamp By turning knob the lamp carriage is shifted forward or backward...

Страница 7: ...n Schutzschirm in Form eines Metallgitters angebracht werden mu um das Herausfallen von gro en Glassplittern im Falle des eventuellen Zerbrechens der Lampe zu vermeiden Ebenso muss aus Sicherheitsgr n...

Страница 8: ...n und arretieren sie die Schnapphalterung nach Beendigung der Operation wieder zur ck auf den Schlitten INBETRIEBNAHME Durch den Neigungs Verstellungs Knebel kann der Scheinwerfer entsprechend positio...

Страница 9: ...eau pour ouverture clapet Coulisse avec culot douille Ressort de r tention plateau de support culot douille Pommeau pour r glage position lampe Poign e pour mouvement projecteur et pour fixation chain...

Страница 10: ...on et modifier son inclinaison On peut faire le m me pour la rotation par rapport l axe vertical en le faisant tourner sur le pivot d attelage la barre porteuse En tournant le pommeau on fait avancer...

Страница 11: ...t poids E B C D F A MOD A mm B mm C mm D mm E mm F mm Kg COM 05 PC 275 208 301 264 150 150 3 6 COM 05 F 252 208 251 215 150 150 3 COM 12 PC 359 265 401 364 200 200 6 8 COM 12 F 330 265 302 264 200 200...

Страница 12: ...e Kodex lm t h K 05 GY 9 5 LC 46 5 300 M 38 5200 2000 2950 300 CP 81 7800 180 3200 500 M 40 10000 2000 2950 500 T 18 11000 360 3050 500 CP 82 13500 180 3200 650 T 26 14500 600 3050 650 CP 89 17500 180...

Отзывы: