Only for variants with pneumatic spring system:
10. Pull up the rubber bellows (
22.1
) on the right-hand side of the spring system (
22
). and connect the
connector (
22.2
) underneath for the pneumatic spring system.
3.2. Electrical connection
Figure 9.
20
20.1
20.2
Electrical connection
Note
The control stand is wired to terminals or plugs/sockets according to the requirements of
the operating organization.
The electrical connection is made specifically according to the connection diagram, the
requirements of the operating organization and the related circuit diagrams,
see chapter
11. “Reference documents”, page 71.
1. Disconnect the system from the supply of electrical power.
2. Open the switch cabinet (
20
) using the related key (
20.1
).
3. Undo the nut on the cable gland and push the nut from the cable gland (
20.2
) onto the wires.
4. Guide the wires through the cable gland (
20.2
) into the switch cabinet (