43
wall protection
INSTALLING ESCORT
Refer to Sections 3.1 and 3.2 on how to calculate the cutting lengths for the
profiles. Once the profiles have been cut to length:
• Once the handrail lengths have been prepared, together with their endcaps, wall returns, brackets and closers, mount them to their respective
wall sections.
• For a handrail height of 900 mm from the floor, use a pencil (or laser) to draw a mark at the required height. The table below shows the drilling
heights according to the ESCORT brackets used:
4.3 PREPARING ESCORT HANDRAILS
4.4 FIXING ESCORT HANDRAILS
Socket screw for
mounting the bracket
TYPE OF BRACKET
POSITION OF THE MARK
FOR A HANDRAIL HEIGHT
AT 900 M
80 mm perforated bracket
MS
845 mm
55 mm bugled bracket
MS3
845 mm
Swan-neck with 70 mm rose
MS03
821 mm - 786 mm
60 mm full bracket
MSP
810 mm
40 mm reduced bracket
MSR
845 mm
60 mm dual-height full bracket
MSDH
800 mm - 725 mm
80 mm quick-removable perforated bracket
MSDE
845 mm
40 mm quick-removable reduced bracket
MSDR
845 mm
Closer
55
80
40
• Slide the brackets into the groove of the aluminium profile.
• Position the end brackets at no more than 50 mm from the end of the profile.
• Set the brackets at maximum intervals of 1,200 mm.
• For short handrail lengths, use at least two brackets at even intervals.
• Fix the brackets to the aluminium profile using a 2.5 mm Allen key.
• Then insert the accessories (endcaps, wall returns, jointing pieces, etc.) into the
profile and secure with the pre-fitted screws until they are flush and hold the
accessory in place.
• Finally, cut the closer to the required lengths and clip into the profile groove.
54
40
40
41
40
40
80
80 mm perforated bracket
MS