24
05 INSTALLATION
Optional: Integration of Xcool
There is the possibility to integrate the cooling unit Xcool into the Xcontrol-E. The relay output signal of the Xcool
can be integrated into the safety circuit, so that in the event of a temperature or flow error, the emergency stop
is activated, and the spindle is stopped.
For integration of the Xcool see wiring diagram below:
Output Pin 1 of the Xcool must be connected to terminal X1:61 (upper row) and output Pin 2 to terminal X1:62
(lower row). Therefore, the bridge between X1:61 and X1:62 must be removed.
Содержание Xcontrol-E
Страница 1: ...OPERATING MANUAL Xcontrol E...
Страница 2: ...spinogy de...
Страница 15: ...15 04 TECHNICAL DESCRIPTION View inside View connection ports...