Re-arming a Deckvest
Remove cylinder and old firing cap by unscrewing anti clockwise. Check firing mechanism
moves freely and free from contamination. Replace new cap first then new cylinder,
ensuring secure fit. Only approved Spinlock Deckware re-arming kits should be used.
UML Pro Sensor
Elite
®
- Part No: DW-RAK/E170 or DW-RAK/E275
Inflating your Deckvest
It is recommended that the following inflation procedures are followed:
1. MANUAL INFLATION
To manually inflate the lifejacket, sharply pull the rubber handle downwards.
The CO
2
gas cylinder should inflate the bladder within seconds.
2. ORAL INFLATION
To inflate the lifejacket by mouth, locate the oral inflation tube by opening the zip at
the yellow breakout point on the front panel of the lifejacket. Then after removing the
end cap, blow into the tube until the lifejacket is fully inflated.
3. AUTOMATIC INFLATION
Inflation should occur automatically within seconds of the inflator unit being
submerged. The automatic capsule is designed to activate a sprung pin to puncture the
CO
2
cylinder and inflate the bladder.
CO
2
Cylinder size: Model 170N: use 33g Model 275N: use 60g
WARNING:
The deck safety harness and safety line may transmit very large forces. Only
attach to strong hooking points or jack-lines.
The deck safety harness and safety line are intented to prevent the user falling
overboard. They do not provide protection from falls at height.
It is unsafe to wear this harness loose, the harness shall be worn tightly in
order to be effective.
INFORMATION: PRESSURE VARIANCE
With variations in air or water temperatures, topping up by oral inflation may be
required to maintain full buoyancy especially after prolonged immersion.
11