1:AZ, 2:AZ
- there are two motors connected to the controller, which is rotated in azimuth
only.
Start
Motors run mode:
MAX SPEED
- motor starts with max speed, that is set for each motor separately in modules
SET MOTOR 1
and
SET MOTOR 2
, described later,
SOFTLY
– so-called soft start. For each motor set in the module
SET MOTOR 1
and
SET MOTOR 2
, described later.
Stop
Motors stop mode:
IMMEDIATELY
– at once,
SOFTLY
– so-called soft stop. For each motor set in the module
SET MOTOR 1
and
SET MOTOR 2
, described later.
External control (CONTROL xx)
This parameter specifies the communication port driver that is used to control the connected motors.
Appears only if the chosen template is different from
1: NC, 2: NC
. If the latter is chosen template
1: AZ, 2: AZ
,
then for each motor, you can choose another port for control.
On display of controller can show few descriptions it depends of selected motors template:
CONTROL A1 – motor template
1:AZ, 2:NC
or
1:AZ, 2:AZ
,
CONTROL E2 – motor template
1:NC, 2:EL
,
CONTROL AE – motor template
1:AZ, 1:EL
,
CONTROL A2 – motor template
1:AZ, 2:AZ
.
CONTROL
parameter value:
NONE
- no external control. Motor controlled manually with buttons on driver,
COM 0
- external control with selected protocol. Can be controlled manually,
COM 1
- external control with selected protocol. Can be controlled manually,
USB
- controlled throughout USB D with selected protocol. Can be controlled manually,
ETH
- controlled throughout ETHERNET with selected protocol. Can be controlled manually.