36
17.
Deinstallation
Warnung
Risk of fatal electric shock
There is a risk of electrocution when working on the electrical components of the wallbox.
►
All work on the electrical components of the wallbox must be carried out by a locally
certified electrician.
►
Disconnect the wallbox from the power supply and secure it against being switched on again.
►
Remove the design cover.
►
Make sure there is no voltage at the device terminals.
►
Disconnect the supply cable.
►
Gently pull all the cables out of the wallbox.
►
Undo the fastening screws.
►
Pack and store the wallbox properly (See 8. Storage, page 9).
18.
Disposal
►
If possible, dispose of the packaging material in the appropriate recycling waste.
Note
►
When you finally discontinue use of the product, please contact your nearest recycling
centre or your dealer for information on the applicable disposal regulations.
19.
Technical data
Pure
Smart Pro
Item number
591 415 01, 591 417 01,
591 515 01, 591 517 01
591 435 01, 591 437 01,
591 535 01, 591 537 01
Rated voltage (U
N
)
230 V AC (1-phase)
400 V AC (3-phase)
Rated operating voltage (U
e
)
230/400 V
Rated frequency (f
n
)
50 Hz
Rated insulation voltage (U
i
)
400 V
Rated impulse withstand voltage
(U
imp
)
4 kV
Rated conditional short-circuit current
(I
cc
)
< 17 kA
Distribution network type
TN/TT
Rated load factor
1
Maximum charging power
3.7 kW (1-phase)
11 kW (3-phase) at 30 °C
Rated current (I
nA
)
16 A
Maximum charging current
16 A (1-phase)
16 A (3-phase) at 30 °C
Preconfiguration
16 A (11 kW, 3-phase)
Connector plug
Type 2 as per IEC 62196-2
Charging mode
3
Degree of protection
IP54
Содержание Wallbox Pure
Страница 1: ...safe inspiring green Product manual Wallbox Pure Wallbox Smart Pro Wallbox Pure Smart Pro ...
Страница 38: ...38 ...
Страница 39: ...39 ...