600 SERIES MANUAL
5
118118-001 Rev A
2.7 INPUT/CONTROL/MONITOR
CONNECTIONS
INPUT POWER CONNECTIONS SERIES
602C/603C/612C ONLY
TERMINAL FUNCTION
1 115/230Vac
Input
2 Neutral
3 Ground
CONTROL AND
MONITORING CONNECTIONS
ALL MODELS
P2/PIN#
FUNCTION
3 Ground
4
Program Input
5 +5Vdc
Reference
6 kV
Monitor
7 Current
Monitor
8
Trip (Short to Gnd)
9 Internal
Program
INPUT POWER CONNECTIONS SERIES
605C/606C ONLY
P2/PIN# FUNCTION
1 +Vcc
Return
2 +Vcc
Input
PIN LAYOUT INPUT/CONTROL/MONITOR
CONNECTOR (P2)
Note:
To obtain local control using the
internal potentiometer accessible at the top
of the unit, jumper P2 pin 4 to pin 9.
For remote potentiometer control connect the
remote potentiometer as follows:
CW terminal to P2 pin 5
CCW terminal to P2 pin 3
Wiper terminal to P2 pin 4
For remote 0 to +5V voltage programming,
apply the input program voltage to P2 pin 4.
For remote TRIP connect P2 pin 8 to P2 pin
3
SECTION III PROGRAMMING OPTIONS
3.1 GENERAL
To provide additional flexibility and
compatibility with earlier models, provision
has been included to allow voltage
programming of all models with a 0 to –5
Volt programming input. There are four
different jumper-selectable modes for
programming. The jumpers for selecting the
required operating mode are located on
PCB100 (the large PCB), easily accessible
upon removal of the cover. Jumper
locations are shown below in Table III-1.
The four modes are described below. The