600 SERIES MANUAL
7
118118-001 Rev A
TABLE III-1 PCB 100 JUMPER
POSITIONS
STANDARD MODE:
Jumper pins 1 to 3, pins 5 to 7
3.3 -5 VOLT PROGRAMMING (for 0 to
100% output voltage) MODE: Jumper pins 1
to 2, pins 3 to 4
3.4
-5 VOLT PROGRAMMING (for 0 to
103% output voltage) MODE: Jumper pins 1
to 2, pins 3 to 5, and pins 6 to 8
3.5 ERIES 612C –5 VOLT
PROGRAMMING MODE: Jumper pins 3 to
5, pins 4 to 6, and pins 7 to 8
TABLE III-2 J3 PIN CONNECTIONS
(Series 612C Option –5VPRO only)
PIN A:
0 to –5Volt programming input
PIN B:
NC
PIN D:
Output voltage monitor (0 to +5V for
0 to maximum HV output)
PIN E:
GND
PIN H:
Output current monitor (0 to +5V for
0 to maximum current out)