Chapter 7
Troubleshooting and Maintenance
7–6
Use the DIP switch test to verify the DIP switch positions.
To perform the DIP switch test:
1. Use the [NEXT] and [PREV] keys to display DIP Switch on the
test selection screen.
DTAM Plus Diagnostic
NEXT to Select Test
ENTER To Initiate
Dipswitch
2. Press [
] to initiate the test.
The DTAM Plus displays the current DIP switch settings.
DIP Switch
Position #1
DIP Switch
Position #6
DIP Switch: 0 0 1 1 0 0
0=OFF
1=ON
Dipswitch
Press ENTER
The 6 positions of the DIP switch are shown in binary format (0 = Off, 1
= On). The leftmost value represents DIP switch position #1.
Note: Position #6 is always shown as 0 regardless of the setting. This
switch position is not used
3. Press
to terminate the DIP switch test and display the next test
selection screen:
DTAM Plus Diagnostic
NEXT to Select Test
ENTER To Initiate
Display Test
4. To terminate the test function , press the [NEXT] or [PREV] keys to
display Reset DUT in the test selection area. Press [
] to reset the
DTAM Plus.
DIP Switch Test
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com