Chapter 1
DTAM Plus OverView
1–12
Operating Parameters
You can set the following parameters using the DTAM Plus menu functions.
Default Value
Function
Parameter
Comm Port
RS-485
Comm Port
RS-232
Remote I/O Port
Baud
19200
2400
2400
Comm Port
Data Bits
8
8
8
Parity
Even
None
None
Baud
9600
9600
9600
Data Bits
8
8
8
Parity
Even
Even
Even
Printer Port
Handshake
Off
Off
Off
LineFeed
Off
Off
Off
Port Enable
On
On
On
Baud
N/A
N/A
230.4K
Rack Size
N/A
N/A
Full
Remote I/O
Last Rack
N/A
N/A
Yes
Port
Rack Number
N/A
N/A
2
Module Group
N/A
N/A
0
DTAM Plus Node
00
N/A
N/A
Special
Max. Node
02
N/A
N/A
Controller Node
01
N/A
N/A
Simulate
Off
Off
Off
Other
Master Code
00000000
00000000
00000000
Scale
On
On
On
DTAM Plus applications are developed off-line using a personal computer
running DTAM Programming Software (DPS). DTAM Plus operating
system upgrades are also transferred using a personal computer.
Use DPS software (Catalog No. 2707-NP, Series H or later) to create
application screens for both the DTAM Plus, DTAM Micro and MicroView
Operator Terminals. For a description of DPS, refer to the Programming
Manual (Publication No. 2707-801).
DTAM
Programming Software
(DPS)