Spectrum Brands 00038877630549 Скачать руководство пользователя страница 2

ENGLISH

ENGLISH

Thank you for purchasing this Pfister product.  All Pfister products are 

carefully engineered, and factory tested to provide long trouble-free use 

under normal conditions.  This product is easy to install using basic tools 

and our easy to follow illustrated instructions.  If you have any questions 

regarding this product, call 1-800-Pfaucet (1-800-732-8238).

1  BEFORE PROCEEDING

 

WARNING: Read all the instructions completely before proceeding. 

Pfister recommends calling a professional if you are uncertain about 

installing this product!

 This product has been designed for use with the Pfister 0X6-140R 

or JX6-140R Roman Tub series rough-in.  It will not work  with any other 

product.

This product should be installed in accordance with all local and state plumbing 

and building codes.  For optimum performance of your new Pfister faucet, a 

minimum water pressure of 25 PSI (172 kPa) is recommended.

Your installation will require supply tubes. To preserve the high flow 

characteristics of these valves, it is necessary to use 

½” I.D. (

” O.D.) copper 

tubing or Pfister Quick Connect Hose Kit 15-136. Consult the store where 

you purchased your faucet for the recommended connections that you may 

require for your area. Before installing your Diverter Valve, Pfister recommends 

installation of a ½” shock arrester before each supply valve.  If deck thickness 

exceeds 1-

¾

” Pfister Stem Extension Kit 974-370 must be used.

2  SHUT OFF WATER SUPPLY

Locate water supply inlets and shut off the water supply valves.  These are 

usually found near the water meter.  If you are replacing an existing faucet, 

remove the faucet from the tub and clean the tub surface thoroughly.

3  TOOLS RECOMMENDED:

For Iron Pipe Installation:

● PTFE Plumber

’s Tape 

 Slotted screwdriver 

 Phillips Screwdriver

 Adjustable wrench 

 Pipe Wrench

 

● Flashlight

● Cloth

For soldered copper and non-standared installations, some additional tools 

may be required.

4  RECOMENDED COMPONENT LOCATIONS

Maximum distance between Diverter Valve (

4A

) and Spray Head Holder (

4B

is not to exceed 16” (406 mm).  

Note:

 Recommended all holes to be 1-

¼” 

(32 mm) diameter.

5  DIVERTER VALVE INSTALLATION

Remove upper Locknut (

5A

) and Washer (

5B

) from Diverter Valve Body (

5C

).  

From underneath deck, insert Diverter Valve Body (

5C

) through deck hole 

(

5D

) and adjust lower Locknut (

5E

) and Washer (

5F

) so that top of Diverter 

Shank (

5G

) is ½

” (13 mm) above Mounting Surface (

5H

).  From above deck, 

place Locknut (

5A

) and Washer (

5B

) onto Diverter Shank (

5G

) and wrench 

tighten until Diverter Valve Body (

5C

) is firmly secured to deck.

6  SPRAY BASE HOLDER INSTALLATION

Connect Spray Holder (

6A

) onto Spray Base (

6B

).  Insert Spray Base (

6B

trough Washer (

6C

) and into Deck Hole (

6D

).  From underneath deck, place 

Washer (

6E

) onto Spray Base Shank (

6F

) and tighten with Locknut (

6G

).  Be 

sure 

Spray Holder (

6A

) is centered and facing forward before final tightening.

3

5

6

4

2

5A

4A

4B

16” (406 mm) MAX.

1-1/4” (32 mm) DIA.

1-3/4” (45 mm) MAX.

1/2” (13 mm)

5G

5H

5F

5E

5B

5D

5C

6A

6F

6C

6D

6E

6G

6B

Содержание 00038877630549

Страница 1: ...original puede 1 llamar al 1 800 Pfaucet 1 800 732 8238 para hablar con un representante de servicio al cliente que lo pueda ayudar o 2 escribir al departamento de servicio al consumidor c o Pfister I...

Страница 2: ...Stem Extension Kit 974 370 must be used 2 SHUT OFF WATER SUPPLY Locate water supply inlets and shut off the water supply valves These are usually found near the water meter If you are replacing an ex...

Страница 3: ...gs wrench tighten and use PTFE Plumber s tape per manufacturer s instructions Whenusingcoppertubing removeallinternalpartsfromcomponents prior to soldering Failure to do so can result in water damage...

Страница 4: ...Handle Hub 12F onto Valve Stem 12G and secure with Screw 12H Hand tighten Decorative Button 12J onto Handle Hub 12F 13 UNIT START UP Turn on hot and cold water supply valves Caution Check all connecti...

Страница 5: ...rim products which contain Porcelain or other similar substance are not acceptable for public areas or Commercial use Installation of Said Trim is at Users Risk 1 800 PFAUCET 1 800 732 8238 For Toll F...

Страница 6: ...ro Generalmente se encuentran cerca del medidor de agua Si est reemplazando un grifo existente retire el grifo de la tina y limpie bien la superficie de la tina 3 HERRAMIENTAS RECOMENDADAS Para la ins...

Страница 7: ...as al largo Para conexiones roscadas apriete con una llave y utilice cinta de plomero de PTFE seg n las instrucciones del fabricante Cuando utilice tubo de cobre quite todas las partes internas de los...

Страница 8: ...vula 12C Instale el cubo de lamanija 12F sobreelv stagodelav lvula 12G ysuj teloconeltornillo 12H Apriete con la mano el bot n decorativo 12J sobre el cubo de la manija 12F 13 FUNCIONAMIENTO DE LA UNI...

Страница 9: ...manijas y el acabado decorativo use solamente un pa o suave y h medo El uso de pulidores detergentes limpiadores abrasivos solventes org nicos o cidos puede provocar da os El uso de algo m s que un p...

Страница 10: ...me Cl molette Cl Stillson Lampe de poche Chiffon Danslecasdesinstallations tuyauteriebras eencuivreetautresnonstandard il se peut que d autres outils soient n cessaires 4 IMPLANTATION RECOMMAND E POUR...

Страница 11: ...raccords filet s les serrer avec une cl et poser du ruban PTFE de plombier conform ment aux instructions du fabricant En cas d utilisation d une tuyauterie en cuivre d poser toutes les pi ces interne...

Страница 12: ...xer au moyen de la vis 12H Serrer le bouton d coratif 12J avec les doigts sur le moyeu de manette 12F 13 MISE EN SERVICE DE L APPAREIL Ouvrir les robinets d eau chaude et d eau froide Attention contr...

Страница 13: ...r et polir toutes les manettes et ornementations d coratives L utilisation de p te polir de d tergents de produits nettoyants abrasifs de solvants organiques ou d acide peut endommager ces pi ces L ut...

Страница 14: ...ronze Le Toscan 19701 DaVinci Lake Forest CA 92610 Phone 1 800 Pfaucet www pfisterfaucets com LG15 407 951 720 Contains ASME A112 18 3 Certified check valves Contiene v lvulas de chequeo certificadas...