![Speck pumps 1.1 THP Dual Voltage Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/speck-pumps/1-1-thp-dual-voltage-series/1-1-thp-dual-voltage-series_installation-operation-and-service-manual_1341838017.webp)
17
Controller Errors
WARNING: The pump must be serviced by a professional service technician qualified in pool/spa installation. The following
procedures must be followed exactly. Improper installation and/or operation can create dangerous electrical hazards, which
can cause high voltage to run through the electrical system. This can cause property damage, serious personal injury, and/
or death. Improper installation and/or operation will void the warranty.
The controller errors are indicated by the red LED and an error code shown in the LED display (See Figure 5). List of error
codes with their descriptions are listed in Table 2.0.
NOTE:
In the event that an error code is shown and will not clear, the controller can be ‘rebooted’ by turning power
to the pump OFF and waiting 10 minutes before turning the power back on. If this step does not clear the error
code, contact your pool professional for service.
6
Troubleshooting
Table 2.0
Figure 5
Error Code
Error Description
01
DC-link over-voltage
02
DC-link under-voltage
03
DC-link voltage is too low
04
IPM (Intelligent Power Module) over-current software protection
05
IPM (Intelligent Power Module) over-current hardware protection
07
AC input over-voltage
08
AC input under-voltage
10
Electronic thermal overload has tripped
11
Motor speed too high
13
IPM (Intelligent Power Module) temperature too high
16
Motor out of step
17
PFC output DC low voltage
20
Short circuit to ground
21
Motor phase short circuit
22
Output phase lack
31
Communication error with master
41
Current sampling sensor error
42
Inrush current preventing relay error
43
Voltage sensor error, AC voltage and DC voltage do not match
51
IPM (Intelligent Power Module) temperature sensor error
60
Motor rotor locked
61
DSP ROM error
62
DSP RAM error
63
DSP watchdog error
66
Internal communication error
ERROR
POWER
SET
OK
0
3
2
1
E 0 5
Содержание 1.1 THP Dual Voltage Series
Страница 27: ...27...