14
Normal Operation
1. To start the pump from the stopped (OFF) position, press the button. The pump will run through the programmed
priming cycle. The priming power level flashes on the LED display and the green LED light above the button flashes during
the priming cycle.
2. Once the priming cycle is complete, the pump will first run on power level setting 1 (S1) for the programmed number of
hours. The power level setting for S1 will be shown on the LED display.
3. After running for the programmed number of hours on S1, the pump automatically changes to S2.
4. After running for the programmed number of hours on S2, the pump automatically changes to S3.
5. After running for the programmed number of hours on S3, and at the end of the 24-cycle, the pump automatically starts
again on S1.
The Factory Default Schedule is:
S1: 200 Watts; 12 Hours
S2: 0 Watts; 0 Hours
S3: 0 Watts; 0 Hours
Under the default schedule, the pump will run at 200W for 12 hours and then remain off for 12 hours every day.
NOTE: The total run time between the three settings (S1 + S2 + S3) must be equal to or less than 24 hours. The
motor will not let the user ave the time settings if the total run time exceeds 24 hours.
NOTE: To save power, the LED display will turn off after three minutes during normal operation.
Power Level
(Watts)
Approx. RPM
1000
2850-3500
850
2800-3250
750
2400-3150
650
2300-3000
550
2150-2850
450
2000-2600
350
1850-2450
250
1650-2150
150
1350-1750
50
850-1050
Table 2
Priming (PR) Menu - Continued
4. The priming time now flashes on the LED display. The factory default setting is two (2) minutes. Use the and buttons
to select the desired priming time between zero (0) and ten (10) minutes, in 1-minute increments. Press the button to
save and exit the priming and programming menus.
1
ERROR
3
OK
2
OK
2
1