15
User Interface Lockout
ERROR
POWER
SET
OK
0
3
2
1
o F F.
Interface
Lockout
Figure 4
Normal Operation - continued
Routine Maintenance
This pump requires little or no service other than reasonable care and periodic cleaning of the strainer basket.
DO NOT
strike
basket to clean. When cleaning the basket inspect the lid o-ring for damage and replace if necessary.
1. Inspect the pump basket for debris by looking through the clear pump lid.
2. Turn OFF the power to the pump. If the pump is located below the water level, close isolation valves on the suction and
discharge sides of the pump to prevent back flow of water.
3. Remove any debris, because as the debris accumulates, it will begin to block the flow of water through the pump. Keep the
basket clean and clear to improve the performance of the pump.
4. Turn the lid ring counter-clockwise to remove. Carefully remove the lid and lock ring.
5. Remove the basket and properly dispose of the debris into the trash and rinse out the basket. Check basket for cracks, if
crack is found replace basket.
6. Replace basket back into the pump, align the basket properly with the suction pipe. Then fill with water up to the suction
pipe. Clean the clear lid, o-ring, and sealing surface of the pump of any debris.
7. Replace lid with lid ring.
Hand-tighten
the lid to make an air-tight seal.
DO NOT use any tools to tighten the lid.
5
Service and Maintenance
To stop the pump at any time, press the “0” button. The pump will come to a stop and the LED display will read OFF.
NOTE: If the power is shut off or the pump is stopped using the “0” button, upon restart the pump will run through the
programmed priming cycle and then resume normal operation.
Reset to Factory Default Settings
Verify that the pump is powered ON and the green power LED light is on.
If the pump is running, press the “0” button to stop it.
Press and hold the “SET” button for at least 15 seconds.
The three preset power level LED lights and the POWER LED light will all illuminate simultaneously to indicate that
factory default settings have been restored.
n
n
n
n
n
To lock the user interface, first press the “SET” button then immediately press the
“0” button simultaneously.
When the user interface is locked, there will be a dot “.” in the lower right corner of
the LED display.
(See Figure 4)
To unlock the user interface, press the “SET” button and “0” button in the same
sequence as described above.
n
n
n
The user interface can be locked to prevent unauthorized programming modifications: