• The burner may only be operated with the burner fleece and these wicks.
It is not permitted to change the number of wicks, the wick material or
the burner fleece.
• The ebios-fire furniture must not be modified.
• This is merely a decorative fireplace for use in the home and is not
intended for heating or continuous operation! Nevertheless, do bear in
mind that heat is generated as a by-product of the combustion process
with the:
Quadra Inside I SL (approx. 3 kW)
Quadra Inside II SL (approx. 6 kW)
Quadra Inside III SL (approx. 6 kW)
This can cause the installation room to heat up under certain
circumstances.
• There should never be any fuel in the tank and the cover must always be
placed on the burner when it is not in use.
• The burners are designed for the fuel to be burnt until all gone. If you
only wish to enjoy the flames for a short period of time, use a corre-
spondingly smaller amount of fuel. If you wish to take the burner out of
operation at an earlier stage than normal, place the cover on the burner
with the aid of the 'cold hand'. After shutting down the burner, always
allow at least 1 hour
• The burner must NOT be filled when warm or alight and must NOT be
filled via the burner channel!
DANGER TO LIFE!
• The handling of fuel in the vicinity of the hot or burning appliance is
associated with significant risks and is not permitted!
• Only fill the burner via the filling opening and never via the burner
channel!
• Should you accidentally spill ethanol, clean this up immediately and
before lighting the burner!
• Please note that the luminosity of the flame can decrease to such an
extent that the flame is no longer clearly visible. Make children and
others in the home aware of this.
• Minimum waiting time between extinguishing and refilling the burner
= 1 hour!
• Do not smoke when handling fuel and operating the ebios-fire.
Failure to follow these basic rules can result in uncontrolled ignition
or even explosions!
4.2 FIRE PROTECTION
Please note: In the radiation area, see Figs. 10 and 14 (in the area of
the flames/furniture) no flammable components and furniture are permitted
within 1000 mm upwards and to the sides (only with ventilated radiation
protection fitted on both sides).
There must be no flammable objects (decorations, clothing etc.) in the
radiation area. In order to guarantee sufficient thermal insulation, there
must be a minimum distance of 1000 mm to flammable components at the
side, furniture, decorations and curtains! There must be no objects between
the fireplace and room ceiling (distance to the ceiling >1000 mm)!
1000 mm