 11

6.  In areas accessible to the public which are not supervised.
7.  In areas which are not protected against transverse ventilation
8.  On tables, pieces of furniture, shelves etc.

3.5 INSTALLATION/ASSEMBLY

The ebios-fire Quadra Inside appliances are turnkey units for installation 
in the cover plate of a bespoke furniture item (combustible materials) or 
in a tailor-made open fireplace (non-combustible materials). No flue gas 
extraction is required for bespoke fireplaces featuring the Quadra Inside SL. 
The ebios-fire furniture item, which may be free-standing or wall-mounted, 
must be aligned horizontally and secured to prevent tilting. Rear ventilation 
must not be closed. Place the burner with reactor containment and cover 
plate into the receiving units provided in the Quadra Inside. Floor-mounted 
furniture may only be set up on floors with sufficient load-bearing capacity. 
If the load bearing capacity is not sufficient, suitable measures must be 

taken (e.g., plate for load distribution) to remedy this.  Use suitable fasten-
ing material (wall plugs, screws etc.) when securing to the wall.
NO design modifications whatsoever are permitted to the design of the 
Quadra Inside SL models.

3.6  GENERAL NOTES FOR INSTALLATION IN BESPOKE 

FURNITURE ITEMS

•  In all cases involving bespoke furniture design for installation with 

Quadra Inside SL, they at least comprise a cover plate/table-top and a 
housing area with an additional air intake. No housing area is needed for 
table-top installations, but it would be advisable to have one.

•  During installation in a bespoke furniture item (combustible materials), 

always bear in mind that the Quadra Inside must NOT be installed in a 
furniture niche. 

Risk of fire!

•  There must be no objects between the Quadra Inside SL and room ceil-

ing (distance to the ceiling >1000 mm)!

•  The Quadra Inside SL may only be installed in the cover plate / table-

tops of a furniture item. (example: bureau, sideboard, pull-out cabinet, 
table)

•  The Quadra Inside must always be bolted to the cover plate / table-top.
•  The furniture items must always be securely mounted to the wall or 

to the floor and secured to prevent any accidental movement, toppling 
and/or lifting action. For this, appropriate fastening material must be 
selected.

•  All inlet apertures and rear ventilation features must be left unob-

structed, and must not be blocked since otherwise a heat build-up would 
take place. 

Risk of fire!

Содержание Quadra Inside I SL

Страница 1: ...Installation and Operating Manual ebios fire Quadra Inside I II III SL...

Страница 2: ...ffer you first class products that will touch your customers emotionally and will inspire feelings such as a feeling of security safety and comfort To achieve this we recommend that you read the opera...

Страница 3: ...3 Quadra Inside III SL 23 3 8 Fire protection minimum distances for fire areas created by craftsmen 24 3 8 1 Quadra Inside I SL 24 3 8 2 Quadra Inside II SL 24 3 8 3 Quadra Inside III SL 24 3 9 Combu...

Страница 4: ...x 6600 Watts Quadra Inside III SL 1 5 l hr approx 0 8 kg hr heat released approx 9900 Watts However the decorative fireplace requires a plentiful supply of fresh air when operated as otherwise the amo...

Страница 5: ...at the commissioning stage on this subject refer to 4 Safety assessment All models may only be operated with the closed housing cover Please note that fuel must not be refilled while the appliance is...

Страница 6: ...Quadra Inside I SL Item Designation Pos Designation A Housing H Filling opening B Burner fleece I Cold Hand C Burner channel K Key tank seal D Cover plate L Bottle for wetting the burner E Stick light...

Страница 7: ...Oldenbourg Verlag Please note that the luminosity of the flame can decrease to such an extent that the flame is no longer clearly visible Make your children and others in the home aware of this These...

Страница 8: ...urg Verlag Please note that the luminosity of the flame can decrease to such an extent that the flame is no longer clearly visible Make your children and others in the home aware of this These details...

Страница 9: ...bourg Verlag Please note that the luminosity of the flame can decrease to such an extent that the flame is no longer clearly visible Make your children and others in the home aware of this These detai...

Страница 10: ...ural conditions and type of use The floor area of the installation must be of a design and size such that the ebios fire can be operated properly and as intended Only permitted and sufficiently strong...

Страница 11: ...ign modifications whatsoever are permitted to the design of the Quadra Inside SL models 3 6 GENERAL NOTES FOR INSTALLATION IN BESPOKE FURNITURE ITEMS In all cases involving bespoke furniture design fo...

Страница 12: ...storage area Storage area and housing area must be sepa rated by a partition floor panel and a back wall 1 Quadra Inside SL 5 Wall mounting 2 Cover plate table top 6 Rear ventilation 3 Housing room 7...

Страница 13: ...must be provided 3 6 1 2 QUADRA INSIDE II SL The minimum dimension of the cover plate table top Fig 6 measures at least 1250 x 400 mm width x depth The cutaway for the Quadra Inside II SL measures 11...

Страница 14: ...dimension of cover plate table top Fig 8 measures at least 1751 x 400 mm width x depth The cutaway for the Quadra Inside III SL measures 1701 x 223 mm and is cut centrally into the cover plate table...

Страница 15: ...ise the housing cover can become covered in soot and the flames may no longer be uniform in appearance Quadra Inside I SL Then the 4 protective panes are installed Quadra Inside II SL Then the 6 prote...

Страница 16: ...e I SL In order to guarantee sufficient thermal insulation there must be a minimum distance of 1000 mm see Fig 16 to flammable components furniture decorations and curtains at the side There must be n...

Страница 17: ...ations and curtains at the side There must be no objects between the ebios fire furniture and room ceiling distance to the ceiling 1000 mm see Fig 19 Fig 17 Minimum distances from wall min min Fig 18...

Страница 18: ...niture decorations and curtains There must be no objects between the ebios fire furniture and the room ceiling distance to the ceiling 1000 mm see Fig 23 Fig 22 Minimum distances in a room corner Fig...

Страница 19: ...ross section at the free aperture for additional air in a furniture unit measures Quadra Inside I SL 200 cm Quadra Inside II SL 400 cm Quadra Inside III SL 600 cm The rear ventilation features must be...

Страница 20: ...t B Corner variant left C Corner variant right D Three sided open variant E Transparent variant Variants of open fireplace inserts Quadra Inside III SL Variants of open fireplace inserts A Front varia...

Страница 21: ...g Tech nology in Berlin DIBt to verify their suitability for use as combustion chamber lining The thermal insulation to be used comprises mats slabs or pipe sections of silica based insulation materia...

Страница 22: ...bility for use as housing area linings The thermal insulation to be used comprises mats slabs or pipe sections of silica based insulation material stone or slag and ceramic fibres of material class A1...

Страница 23: ...suitability for use as combus tion chamber linings The thermal insulation to be used includes mats slabs or pipe sections of silica based insulation material stone or slag and ceramic fibres of mater...

Страница 24: ...esh air to the room in which the fire is installed It is possible that there is not a sufficient supply of fresh air if the windows and doors are sealed e g in combination with energy saving measures...

Страница 25: ...ildren elderly or infirm persons As is the case with all open flames it is expedient that you attach a protective fixture for these groups of persons available as an accessory from specialist dealers...

Страница 26: ...illed via the burner channel DANGER TO LIFE The handling of fuel in the vicinity of the hot or burning appliance is associated with significant risks and is not permitted Only fill the burner via the...

Страница 27: ...ely for combustion and it not suit able for consumption Supervise your children If swallowed consult a doctor immediately and present the fuel label 4 4 COMMISSIONING The ebios fire Quadra Inside is s...

Страница 28: ...ead maintains a uniform distance from the burner channel Then insert the protective panes 12 Insert the cold hand to grip the cover plate and lift it off 13 Wet the burner fleece with fuel using the b...

Страница 29: ...the housing cover Depending on the installation situation the protective panes may need to be removed When being installed in a bespoke fire area chimney system the burner should be filled outside the...

Страница 30: ...the room and on the furnishings where the fire is installed 6 MAINTENANCE TROUBLESHOOTING The wick and burner fleece must be visually inspected at regular inter vals The material can be easily damage...

Страница 31: ...s apply for the contractual relationship between the manufacturer Spartherm Feuerungstechnik GmbH and the dealer distributor They are not congruent with the contractual and warranty terms which the de...

Страница 32: ...reless handling of fragile components such as glass or ceramics improper operation and or use incorrect filling of system lack of maintenance incorrect set up installation of device failure to comply...

Страница 33: ...respect of statutory legal requirements 7 10 CLOSING REMARKS In addition to these warranty conditions and our commitment to them our dealers and contractual partners are pledged to assist you in both...

Страница 34: ...rom being classified in accordance with applicable legislation on standards Unlike with the Quadra Inside I SL the models Quadra Inside II SL III SL are not covered by the DIN 4734 1 standard and cann...

Страница 35: ...GB GB 35 NOTES...

Страница 36: ...merk van wereldformaat voor uw woonkamer wiatowa marka do Pa stwa salonu 1 D Ihr Fachh ndler UK Your specialist dealer F Votre revendeur sp cialis IT Il vostro rivenditore specializzato E Sus comerci...

Отзывы: