SINCE 1943
FOR TOUGH CUSTOMERS.
PRODUCT MANUAL
Sewer Inspection Camera
© 2020 Spartan Tool LLC
Part #64052025
Spartan Tool LLC
|
1618 Terminal Road
Niles, Michigan 49120
order by phone
800.435.3866
order online
SpartanTool.com
Страница 1: ...FOR TOUGH CUSTOMERS PRODUCT MANUAL Sewer Inspection Camera 2020 Spartan Tool LLC Part 64052025 Spartan Tool LLC 1618 Terminal Road Niles Michigan 49120 order by phone 800 435 3866 order online Sparta...
Страница 2: ...tings Menu 14 START UP GUIDE 15 Camera Connection and Removal 15 Connectivity 16 Mounting the Control Box 17 Plug Socket Engagement 17 Brake Operation 18 Push Rod Instructions 18 Sonde Locator Operati...
Страница 3: ...TERFACE 24 Counter 25 Counter Reset 25 Recording 25 Viewing copy and deleting recordings 25 Viewing Recordings 25 Deleting Recordings 25 Transferring Files 25 Light Adjustment 26 File Manager 26 Mina...
Страница 4: ...a risk of death or injury could occur Atex This symbol is in reference to areas specific to explosion proof camera systems This is not applicable for this system Caution This icon points out dangers...
Страница 5: ...s to ensure there is NO damage Thoroughly inspect equipment to determine that it will operate properly and perform its intended function NOTE When using a TrapJumper it is critical that the user has r...
Страница 6: ...been swallowed i All replacement batteries must be supplied and installed by Spartan Tool LLC j Keep cells and batteries clean and dry k After extended periods of storage it may be necessary to charge...
Страница 7: ...s or vapors or by combustible dusts If there is enough of the substance mixed with air then all it needs is a source of ignition to cause an explosion Never use a Spartan Tool inspection system in pip...
Страница 8: ...ant at all times be aware of your surroundings and use the correct personal protetctive equipment tools warning signs barriers etc RISK DETAILS OF SPECIFIC HAZARD CONFINED SPACE Working in a confined...
Страница 9: ...ence They would also be familiar with the appropriate health and safety regulations as well as accident prevention giving them the knowledge to operate the inspection system within safe working condit...
Страница 10: ...10 Product Overview The TrapJumper system consists of the following components 1 System box 2 Coiler 3 Push rod 4 Camera head The following sketch demonstrates a typical set up 1 2 3 4...
Страница 11: ...1 Help button 2 mina survey 3 Wincan survey 4 General text overlay 5 Text font 6 Text size 7 Meterage placement 8 File manager 9 Settings 10 Sonde ON OFF button 11 Lights OFF 12 Power ON OFF 13 Light...
Страница 12: ...tus not applicable with TrapJumper this allows users to determine whether the camera is water tight 6 LED brightness indicates the level of brightness 7 Counter placement allows the user to position t...
Страница 13: ...13 Product Overview Camera connected Recording Pressure ok Sonde switched ON Sonde frequency...
Страница 14: ...e components Users can adjust the time date connect to WinCan Web and view the camera temperature pressure Product Overview System details Temperature Pressure sensor 2 Pressure sensor 1 Onscreen coun...
Страница 15: ...nector into the rod Spring end 12mm Wrench Tighten Loosen 3 Finally screw the spring over the rod connector hand tight Repeat this process in reverse to remove the camera head NOTE If the spring is di...
Страница 16: ...de USB 1 USB 2 SD Card Socket Ethernet Socket Headphones Microphone Pressure valve Monitor lead input socket 10 pin Identification label VGA output Battery charging socket Monitor lead input socket 7...
Страница 17: ...nst the handle 4 Check the box is central to the frame NOTE To remove the box disconnect the cables and repeat the steps above in reverse PLUG SOCKET ENGAGEMENT 7 pin din Align the keyway clip at 12 o...
Страница 18: ...o align the rod and do not cross it over This will reduce the risk of damage and an imprecise meterage reading CAUTION Excessive force on the push rod will cause damage and can even snap the inner cor...
Страница 19: ...connected from power supply Do not expose mains cables charges to rain or moisture Keep all power cables clean Contamination will increase the risk of electric shock Connect all cables in accordance w...
Страница 20: ...power cord using PSU Charging begins as soon as power is connected The charging procedure automatically recognizes the charge state of the battery Charge current will fluctuate according to the batte...
Страница 21: ...ion What matters most is how you charge your battery after you ve started using it Shallow discharges and recharges are better than full ones because you put less stress on the battery so it lasts lon...
Страница 22: ...duction in the danger of catching infections from the equipment if cleaned thoroughly after each use The following list provides a guide on some care and maintenance measures that should be applied wh...
Страница 23: ...e Description 30mm TrapJumper Camera Head TrapJumper Slip Skid 64051824 TrapJumper Skid 60mm OD 64051825 TrapJumper Skid 85mm OD 64051826 NOTE Ensure the grub screw threads remain clean of grit and ot...
Страница 24: ...s the text overlay key 2 key changes the size of text 3 key changes the font color of text 4 Use SHIFT and the Arrow keys to move the text around the screen 5 Press OK when the text is in the correct...
Страница 25: ...vice like a USB is inserted The inserted devide then becomes the default NOTE In basic recording mode the Explorer control box will record exactly what appears on the screen as long as it has been sta...
Страница 26: ...be played or images viewed Press Esc or the left arrow key to go back a step Continued back step will take you out of file manager SURVEY 1 Press the mina icon button and select New Project This will...
Страница 27: ...lize project will generate this for you If you fail to finalize a project WinCan office software will not recognize the file NOTE Project job name Upstream Node Ref Downstream Node Ref Pipe material i...
Страница 28: ...GB SVGA LCD Viewing Angle 85 typical IP Rating Box IP54 open IP67 closed Camera IP68 Memory 32 GB SSD Data Export x2 USB 2 1 x1 SD card x1 Ethernet Wifi 4G Software WinCan Embedded WinCan Web Basic mi...
Страница 29: ...29 Notes...
Страница 30: ...SINCE 1943 FOR TOUGH CUSTOMERS CONTACT US Spartan Tool LLC 1618 Terminal Road Niles MI 49120 800 435 3866 SpartanTool com Part 64052025 Rev 04 2020...