CLEARANCES TO COMBUSTIBLES
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than
3
Follow these instructions carefully to ensure safe installation. Failure to follow instructions
exactly can create a fire hazard.
WARNING
any non-combustible ma-
6
6
6
6
6
6
12"
maximum
depth
COMBUSTIBLE MANTEL
Combustibles
Clearance to
INSTALLATION
9
Minimum
16
"
from both side
walls
90" minimum
ceiling height
Standoff
0"
(0 mm)
terial
(refer to pages 10-18)
.
*) IMPORTANT:
Floor must be non-combustible
. Otherwise a minimum
1" thick
cement board must be placed under the fireplace.
The fireplace face m
ay
be
completely covered with
Sides
0"
(0 mm)
Floor
*
)
Back
0.5" (13 mm)
H minimum **)
**) H = 20" for Models SS-36 (N,P) and SS-48 (N,P)
H = 30" for Models SS-60 (N,P) and SS-72 (N,P)
/
4
" from the facing. If it does, it
is considered a mantel and must meet the mantel requirements listed in this manual.