![Spark SS-36-N Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/spark/ss-36-n/ss-36-n_owners-operation-and-instruction-manual_1339532016.webp)
NOTICE: Most building codes
do not permit concealed gas
connections. A flexible gas line
is provided to allow
shutoff
valve should be accessible.
INSTALLATION
Continued
Flexible Gas Line
from Fireplace
Gas Regulator
To Fireplace
Gas Regulator
Equipment
Shutoff Valve
Provided by
Installer
Propane/LP
To External
Regulator
Natural Gas
To Gas Meter
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
sediment trap where it is within reach for clean-
ing. Install in piping system between fuel supply
and fireplace. Locate sediment trap where trapped
matter is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them from
going into fireplace gas controls. If sediment trap
is not installed or is installed wrong, fireplace may
not run properly.
CONNECTING FIREPLACE TO GAS
SUPPLY
1
. Remove
access
panel.
2
. Route gas line (provided by installer) from
equipment shutoff valve to fireplace. Route
flexible gas supply line through one of the
access holes.
3
.
Attach the flexible gas line to gas supply as
CHECKING GAS PRESSURE
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
is different from the fireplace, STOP! Do not install the
appliance. Contact your dealer immediately.
2. To ease installation, a 30" (mm) flex line with manual
shut-off valve has been provided with on this appliance.
Install and attach
1
/
2
" gas line onto shut-off valve.
Outlet Pressure Tap
Pilot Adjustment
Inlet Pressure Tap
4.
Do not use open flame to check for gas leaks.
WARNING
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to the
fireplace for leaks. Use a solution of 50/50 water and
soap or a gas sniffer.
T
o check g as pressures at t h e v alve, turn captured
screw counter clockwise 2 or 3 turns and then place
tubing to pressure gauge over test point.
Turn unit to high. After taking pressure reading,
be sure and turn captured screw clockwise
firmly to reaseal. Do not overtorque. Check
test points for gas leaks!
Figure
5
- Attaching Flexible Gas Lines
Together
per Figure
5. Check tightness of flexible gas
l
ine attached to gas regulator of fireplace and
check all gas connections for leaks ( see
accessibility
from
the
fireplace
(see Figure 5)
. The
flexible gas supply line con-
nection to the equipment
Checking Gas Connections
, page
21).
We recommend that you install a sediment trap in
supply line as shown in Figure
4
, page
1
9
.
Locate
16