7
on
off
Mode
SET
off
on
AUTO
on
off
Mode
SET
off
on
AUTO
on
off
Mode
SET
off
on
AUTO
on
off
Mode
SET
off
on
AUTO
Parameter 0:
Cooling setting water
temperature (10-45°C).
Factory setting: 27°C
Parameter 2:
Turnround if defrosting
under heat mode (30-90 min).
Factory setting: 45 minutes
Parameter 1:
Heating setting water
temperature (10-45°C).
Factory setting: 27°C
Parameter 3:
Defrosting start temperature
(-30-0°C). Factory setting: -7°C
0 27
2 45
1 27
3 -7
3.2 Set the Operation Parameter
1. Press & hold the “SET” button for 5 seconds to enter the operation parameter setting
interface.
2. Press or to check parameter.
(parameter from 0-P, see Operation Parameter Table).
3. Under parameter, press “ SET “ to start setting (the parameter displayed blinks).
Press or to set data for parameter from 0-d. Press “ SET “ again to exit the
current parameter settings.
4. Wait for 5 seconds. The LCD screen will display the water temperature (If heat pump is
running) or the current time (if the heat pump is OFF).
5. Whilst the unit is running, you can press & hold the “SET” button for 5 seconds to check
the current parameter, but you cannot change the value.