Unless you are certain the heat pump has always remained in its upright
installation orientation during transit and throughout the installation process, and has
not been laid on its side or end at any time, the heat pump should NOT be used for 24
hours after its installation to prevent damage to the compressor.
• The heat pump is pre-installed with a power cable for direct power connection
to a suitable power point. If the installer decides to connect power to the heat pump from
a source, all electrical connections must be performed by a licensed electrician and must
confirm to all national, state and local electrical codes in effect at the time of installation.
• The heat pump must be connected to a suitable rated and weather protected power
supply. The supply line should be a dedicated power circuit and means for disconnection
must be incorporated in the fixed wiring in accordance with your local wiring regulations.
Means for disconnection from the supply mains should have a contact separation in all
poles that provide full disconnection under over voltage Category III conditions.
• The appliance contains no serviceable parts. Do not attempt service of this appliance.
Contact your dealer or authorized service agent for assistance.
• Turn the mains power OFF before touching or modifying any cable connection.
• Low voltage or improper wiring may cause damage to this appliance. Read and follow
all wiring instructions when connecting to power supply.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
• This appliance must not be installed in proximity to highly flammable materials.
• Water temperature in excess of 38oC may cause hyperthermia (heat stress).
• It is the installer’s responsibility to ensure the floor or mounting base is capable of
supporting the expected load of the heat pump and an adequate drainage system has to
be provided in case of overflowing or leaking water.
• The heat pump should be plumbed after the spa filters and NOT before, to prevent
foreign objects or debris from entering heat pump.
WARNING:
When ambient temperatures are close to or under freezing point, water
circulation to the heat pump should never be stopped for more than 4 hours without
completely draining the heat exchange.
In areas where freezing conditions are
prevalent and sustained, in advance of any freeze event, all water MUST be removed
from the entire heat pump water circuit. Please refer to the “Winterising” section of
this manual. FREEZE DAMAGE NOT COVERED UNDER PRODUCT WARRANTY