www.spacemanusa.com
Phone: (720) 328-1020
Email: [email protected]
Frozen Product Operation
Located directly above the draw valve, this arm tells the machine when product is being dispensed
and how firm the product is. Beater and cooling systems are turned on and off based on information
from the sensor arms.
Adjust product consistency
The viscosity adjustment screw, located above the draw handle, controls the
firmness of dispensed product. The higher the viscosity, the more firm the
product. Viscosity settings should NOT need continuous adjustment.
To adjust product consistency, use a #2 Phillips-head screwdriver to turn the
viscosity adjustment screw. Make small adjustments each time, and allow at
least 10 to 15 minutes between adjustments to evaluate product firmness.
Increase viscosity (more firm):
Turn viscosity adjustment screw clockwise.
Turn a maximum of two full turns per adjustment.
Decrease viscosity (less firm)
Turn viscosity adjustment screw counter-clockwise.
Turn a maximum of two full turns per adjustment.
WARNING: STOP turning
viscosity adjustment
screw if you feel any
increase in resistance to
prevent damage.
Curved arm moves up and down
and tells machine when product
is being dispensed.
It moves UP when draw handle is
in the OPEN position.
Flat arm moves left and right and
tells machine when product is at
desired consistency.
Switched RIGHT means
consistency is correct. Switched
LEFT or IN THE MIDDLE means
consistency is not yet correct.
16
Manage sensor arms