background image

 

WIDE RANGING APPLICATION: 

Food preparation, Safety and Fire inspectors, Plastic molding, Asphalt, Marine and Screen printing, 

measure ink and Dryer temperature, HVAC/R, Diesel and Fleet maintenance. 

 

 
        

SAFETY 

 

 

Use extreme caution when the laser beam is turned on. 

 

Do not let the beam enter your eyes, another person’s eyes or the eyes 

of an animal. 

 

Be careful not to let the beam on a reflective surface strike your eye. 

 

Do not allow the laser light beam impinge on any gas which can explode. 

Note: 

This mini infrared thermometer should not be used for medical or 

veterinary purposes due to: 

 

Risk of the laser pointer entering the subjects’ eyes (serious damage to the eye can occur). 

 

This thermometer accurately measures surface temperature, the surface temperature of a 

subjects skin will vary from that of their core temperature. 

 

 

DISTANCE & SPOT SIZE 

As the distance (D) from the object increases, the spot size (S) of the area measured by the unit 
becomes larger. The relationship between distance and spot size for each unit is listed below. The 
focal point for each unit is 914mm (36”). The spot sizes indicate 90% encircled energy. 

Fig: 1  

 

 

 

 

 

 

D:S= 12:1

D

S

12in.

1in @

6in.

0.5in @

25mm @300mm

150mm

12.5mm @

Note: 

Field of View

: Make sure that the target 

is larger than the unit’s spot size.  

The smaller the target, the closer you 

should be to it.  

When accuracy is critical, make sure the 

target is at least twice as large as the spot 

size. 

Содержание SP62020

Страница 1: ...S AND ATTACH RECEIPT TO MANUAL FOR FUTURE REFERENCE NOTE Proof of purchase must be retained by the customer as it will be required in the event of a claim under warranty AFTER SALES SUPPORT AUSTRALIA...

Страница 2: ...ient ergonomic operation Non contact Infrared Thermometers can be used to measure the temperature of an objects surface that is unsuitable to be measured by traditional contact means such as moving ob...

Страница 3: ...inter entering the subjects eyes serious damage to the eye can occur This thermometer accurately measures surface temperature the surface temperature of a subjects skin will vary from that of their co...

Страница 4: ...8 1202 F 0 5 or 0 5 C 0 9 F Response time 150ms Spectral response 8 14um Emissivity Digitally adjustable from 0 10 to 1 0 Over range indication LCD will show Polarity Automatic no indication for posit...

Страница 5: ...ature value BUTTONS 1 Up button for EMS HAL LAL 2 Down button for EMS HAL LAL 3 Mode button for cycling through the mode loop Functional Design 1 Switch between C F using switch underneath battery cov...

Страница 6: ...ff Press the Measurment Trigger to confirm the lock measurement mode The IR Thermometer will display the temperature until the Meas urement Trigger is pressed again In Lock mode press the up or down b...

Страница 7: ...mperature HAL is on a red LED will flash on the LCD During measurement if the measured temperature is lower than the Low Alarm LAL temperature LAL is on a red LED will flash on the LCD Note Measuremen...

Страница 8: ...meter outside the area of interest then scan across with an up and down motion until you locate hot spot Reminders 1 Not recommended for use in measuring shiny or polished metal surfaces stainless ste...

Страница 9: ...0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Timber 0 90 Ceramic 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 Chromium...

Страница 10: ...or normal wear and tear 1 2 Has been used in a manner other than for which it was originally designed 1 3 Has been tampered with or is otherwise than as supplied by SP Tools 1 4 Where any damage malfu...

Отзывы: