FRONT PANEL DESCRIPTION

 

1)

 

IR sensor 

2)

 

LCD Display Laser pointer beam 

3)

 

Up button 

4)

 

Down button 

5)

 

Mode button 

6)

 

Measure trigger 

7)

 

Battery Cover 

8)

 

       Handle Grip 

 

 

 

INDICATOR 

1)

 

Data hold 

2)

 

Laser “on” symbols 

3)

 

Lock symbol 

4)

 

High alarm and low alarm symbol 

5)

 

˚C / ˚F symbol

 

6)

 

Low power symbol 

7)

 

Emissivity symbol and value 

8)

 

Temperature values for the MAX 

9)

 

Symbols for MAX 

10)

 

Current temperature value 

 

 

BUTTONS 

1)

 

Up button for EMS, HAL, LAL 

2)

 

Down button for EMS, HAL, LAL 

3)

 

Mode button for cycling through the mode loop 

 

 

Functional Design 

1)

 

Switch between ˚C / ˚F using switch underneath battery cover.

 

2)

 

In Measuring mode use the Up and Down buttons to adjust the Emissivity. 

3)

 

In Hold mode, use Up key to turn the laser on or off. Use Down key to turn the backlight on 

or off. 

4)

 

To set values for the High Alarm (

HAL

), Low Alarm

 

(

LAL

) and Emissivity (

EMS

), press the Mode 

button until the appropriate code appears in the display, press the Up and Down

 

buttons to 

adjust the desired values. 

 

 

 

Содержание SP62020

Страница 1: ...S AND ATTACH RECEIPT TO MANUAL FOR FUTURE REFERENCE NOTE Proof of purchase must be retained by the customer as it will be required in the event of a claim under warranty AFTER SALES SUPPORT AUSTRALIA...

Страница 2: ...ient ergonomic operation Non contact Infrared Thermometers can be used to measure the temperature of an objects surface that is unsuitable to be measured by traditional contact means such as moving ob...

Страница 3: ...inter entering the subjects eyes serious damage to the eye can occur This thermometer accurately measures surface temperature the surface temperature of a subjects skin will vary from that of their co...

Страница 4: ...8 1202 F 0 5 or 0 5 C 0 9 F Response time 150ms Spectral response 8 14um Emissivity Digitally adjustable from 0 10 to 1 0 Over range indication LCD will show Polarity Automatic no indication for posit...

Страница 5: ...ature value BUTTONS 1 Up button for EMS HAL LAL 2 Down button for EMS HAL LAL 3 Mode button for cycling through the mode loop Functional Design 1 Switch between C F using switch underneath battery cov...

Страница 6: ...ff Press the Measurment Trigger to confirm the lock measurement mode The IR Thermometer will display the temperature until the Meas urement Trigger is pressed again In Lock mode press the up or down b...

Страница 7: ...mperature HAL is on a red LED will flash on the LCD During measurement if the measured temperature is lower than the Low Alarm LAL temperature LAL is on a red LED will flash on the LCD Note Measuremen...

Страница 8: ...meter outside the area of interest then scan across with an up and down motion until you locate hot spot Reminders 1 Not recommended for use in measuring shiny or polished metal surfaces stainless ste...

Страница 9: ...0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Timber 0 90 Ceramic 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 Chromium...

Страница 10: ...or normal wear and tear 1 2 Has been used in a manner other than for which it was originally designed 1 3 Has been tampered with or is otherwise than as supplied by SP Tools 1 4 Where any damage malfu...