manualshive.com logo in svg
background image

Rev

 

1.1,

 

7/28/11

 

 

BACnet

 

T

­

Stat

 

by

 

Quest

 

Controls

 

User’s

 

Manual

 

Rev

 

1.1

 

 

 

 

 

 

COPYRIGHT

 

NOTICE

 

Copyright

 

©

 

2011

 

by

 

Quest

 

Controls

 

Inc.

 

(QUEST).

 

The

 

material

 

discussed

 

in

 

this

 

publication

 

is

 

the

 

proprietary

 

property

 

of

 

QUEST.

 

QUEST

 

retains

 

all

 

rights

 

to

 

reproduction

 

and

 

distribution

 

of

 

this

 

publication.

 

Specifications

 

are

 

subject

 

to

 

change

 

without

 

notice.

 

Содержание BACnet T-Stat

Страница 1: ...COPYRIGHT NOTICE Copyright 2011 by Quest Controls Inc QUEST The material discussed in this publication is the proprietary property of QUEST QUEST retains all rights to reproduction and distribution of...

Страница 2: ...1 Programming flow 7 3 4 2 Sub Menus 7 4 0 BacNET Programming 9 5 0 OspreyFMS Interface 9 5 1 Logging In 9 5 2 Main Dashboard Page 9 5 3 Programming Page 10 6 0 Setting Communications Jumpers 11 6 1...

Страница 3: ...d temp sensor making it suitable for zone mounting or remote input for panel mounting The BACnet T Stat includes an additional 4 20 milliamp input digital input and analog digital outputs 1 1 Applicat...

Страница 4: ...uld be near eye level on an interior wall and away from external sources of heat or cold windows doors HVAC supply ducts Servers etc 2 Prepare the Area The mounting screw holes will line up on a stand...

Страница 5: ...e sensor set Jumper ZONE J1 2 to top middle and SENS SPOT to off on front panel SUPPLY Supply Duct temperature sensor SUPPLY FAN P FAN Proof of Run current transducer FAN P MA 24 mA input for optional...

Страница 6: ...P DO D1 C BUS R C G Y 1 Y2 W B W2 O FAN COOL HEAT WIRE RACEWAY CT 24VAC R C F Y1 Y2 W1 W2 Supply Fan Cool Stage 1 Cool Stage 2 Heat Stage 1 Heat Stage 2 HVAC Control Interface Located in HVAC system F...

Страница 7: ...e If you choose Yes then the T Stat will be in occupied override mode for the programmed delay time or unless the user presses the center button again to disable the occupied override mode 3 3 Adjusti...

Страница 8: ...81 F Cool1 Fan Auto Access Code 11 Program Choices System Program Choices Run Program Choices Schedules Program Choices Clock Program Choices Setpoints Entering System Menu Entering Run Menu Entering...

Страница 9: ...the field s value and the left right arrow keys to change to the hours and minutes fields Time is entered in 24 hour format Press the center button to accept the changes to the window and move to the...

Страница 10: ...r contact Quest Controls for more information 5 1 Logging In OspreyFMS is compatible with most versions of Internet Explorer Firefox Chrome and Safari running on Windows OS OS X iOS or any operating s...

Страница 11: ...ller Programming button at the bottom right 5 3 Programming Page The programming page provides an interface for making any change to program settings on the BACnet thermostat The page also provides to...

Страница 12: ...ounting plate and turn over the T Stat to locate the jumpers Refer to Figure 5 for jumper identification and settings 6 1 RS485 End of Line and Biasing Wiring of the RS485 network will require the use...

Страница 13: ...ins1 2 enables End of Line Resistor Future Use Jumper on pins1 2 enables Line Biasing Jumper on pins1 2 enables Line Biasing Future Use Denotes pin1 Jumper on pins1 2 when using a Remote Zone Temperat...

Страница 14: ...not engage Verify connection to HVAC unit Ensure short cycle timer is not inhibiting unit Clock loses time after power failure Replace the CR1025 Lithium battery Buttons do not respond Press buttons...

Страница 15: ...lative Humidity 0 to 95 non condensing Enclosure Color Quest White Dimensions 3 65 x 5 30 x 1 5 300mm x 200mm x 100mm Shipping Weight 0 75lbs 34kg Agency Approvals UL UL873 US and CSA C22 2 No 24 Cana...

Страница 16: ...central server with capabilities for expanded functions such as demand response curtailment and internet based outdoor air temperature BACnet Standardized Device Profile Annex L BACnet Operator Workst...

Страница 17: ...f 150F indicates a shorted sensor condition AI 1 Raw Supply Air N Fahrenheit or Celsius reading of the supply air thermistor directly from the sensor no offsets applied A reading of 25F indicates an o...

Страница 18: ...42F 90F 74F Occupied stage 1 cooling setpoint AV 6 Unoccupied Cool Spt Y TempF or TempC 42F 90F 85F Unoccupied stage 1 cooling setpoint AV 7 Occupied Heat Spt Y TempF or TempC 40F 88F 68F Occupied sta...

Страница 19: ...e zone sensor reading corrected with the zone offset AI0 AV2 AV 20 Supply Reading Y TempF or TempC 25F 150F N A The supply sensor reading correct with the supply offset AI1 AV3 AV 21 Restart Delay Y S...

Страница 20: ...d Win 2 End Y Minutes 0 1440 0 Number of minutes since midnight to end occupied mode for this window Set both the Start and End values to 0 to mark this window as unused AV 33 Wed Sched Win 1 Start Y...

Страница 21: ...ed mode for this window AV 44 Fri Sched Win 2 End Y Minutes 0 1440 0 Number of minutes since midnight to end occupied mode for this window Set both the Start and End values to 0 to mark this window as...

Страница 22: ...pF or TempC 0 AV16 N A The current setpoint offset a user has entered via the front panel AV 54 Front Panel Code Y None 0 11 99 0 The access code a user must enter to use the front panel programming m...

Страница 23: ...net occupied override 1 Enable BACnet occupied override BV 4 Zone Sensor Location Y 0 0 Use onboard zone thermistor 1 Use remote mounted zone thermistor Binary Output Object Detail Supported Propertie...

Страница 24: ...Output O Y 0 De energize Output 1 Energize Output 255 Remove bypass Multistate Input Object Detail Supported Properties Writable Property Range Restrictions Object Identifier N N A Object Name N N A...

Страница 25: ...t id is the MSTP Network 1000 the MAC address Object Name N QSTAT10000 0 1 N A Built up with model name MSTP Network Address MAC Address Object Type N N A N A Description N Qstat10000 N A Model Name N...

Страница 26: ...MS TP master Clause 9 baud rate s 9600 19200 38400 57600 76800 MS TP slave Clause 9 baud rate s 9600 19200 38400 57600 76800 Point To Point EIA 232 Clause 10 baud rate s Point To Point modem Clause 1...

Страница 27: ...BIBB Multiple Application Specific Keys Supports encryption NS ED BIBB Key Server NS KS BIBB Character Sets Supported Indicating support for multiple character sets does not imply that they can all b...

Страница 28: ...BACnet T Stat User s Manual Rev 1 1 7 28 11 Page 14 Attachment 2 Osprey Programming Page...

Отзывы: