background image

If you are not a professional installer and want to install tado° 

yourself, get step-by-step instructions at tado.com/start

Smart Thermostat

230 V Relay Installations

Guide for Professional Installers

United Kingdom

Part 1 of 2

Summary of Contents for 230v

Page 1: ...ot a professional installer and want to install tado yourself get step by step instructions at tado com start Smart Thermostat 230 V Relay Installations Guide for Professional Installers United Kingdom Part 1 of 2 ...

Page 2: ......

Page 3: ... 6 Extension Kit Combi Boilers Dry Contacts 7 Extension Kit S Plan Setups Switched Live 8 Extension Kit Y Plan Setups Switched Live 9 2 Connect Internet Bridge to Router 10 3 Pair Extension Kit with Internet Bridge 11 4 Pair Smart Thermostat with Internet Bridge 12 5 Configuration 14 ...

Page 4: ...4 CAUTION High voltage cables Make sure to turn the power off before you start Do not use the tado relay to switch the main electrical supply to the boiler 08 2018 ...

Page 5: ...5 Optional Accessory Use the tado Trim Plate behind the Smart Thermostat or Extension Kit if needed This can be obtained separately at tado com trim plate ...

Page 6: ...at Wired Setup Smart Thermostat is wired directly to the boiler MAX 230 V AC 6 4 A Smart Thermostat Boiler The Smart Thermostat can also be installed wirelessly when the Extension Kit is wired p 7 9 Parking Terminals Combi Boilers Dry Contacts ...

Page 7: ...g Extension Kit Combi Boilers Dry Contacts MAX 230 V AC 6 4 A Wireless Setup Smart Thermostat installed wirelessly with receiver Extension Kit 1 Jumper Position 1 COM NC NO Boiler Smart Thermostat Extension Kit ...

Page 8: ...witched Live Extension Kit MAX 230 V AC 6 4 A 2 Hot Water Valve Hot Water Tank Boiler Jumper Position 2 HW OFF CH OFF HW ON CH ON Heating Valve Wireless Setup Smart Thermostat installed wirelessly with receiver Smart Thermostat Extension Kit ...

Page 9: ...lan Setups Switched Live Extension Kit MAX 230 V AC 6 4 A 2 Boiler Valve Hot Water Tank Jumper Position 2 HW OFF CH OFF HW ON CH ON Wireless Setup Smart Thermostat installed wirelessly with receiver Smart Thermostat Extension Kit ...

Page 10: ...ge to Router Connect Internet Bridge to router Press pairing button until the LED blinks to activate pairing mode Pairing allows other devices to connect to the Internet Bridge If no free USB jack available plug to power socket ...

Page 11: ...g fast Paired Fast Blinking 3 SEC 2 MIN Blinking 4x short pause Wireless Setup Smart Thermostat installed wirelessly with receiver Smart Thermostat Extension Kit If failed Restart pairing and make sure that the distance between the devices is at least 3 m while pairing Blinking 2x short pause ...

Page 12: ...idge 3 SEC 2 MIN Press button for 3 sec release Paired Remove battery strip and press button Pairing If failed Press the button to clear the error Restart pairing and make sure that the distance between the devices is at least 3 m while pairing ...

Page 13: ...elease Press button for 3 sec release Installer Menu is loading Ready for configuration If failed Repeat the process to open Installer Menu Make sure that the distance between the devices is at least 3 m while loading the menu Open Installer Menu ...

Page 14: ...e Sensor TS Heating Circuit HC01 Activate Hot Water Control for S and Y plan wiring only 5 Configuration Wired Setup Smart Thermostat is wired directly to the boiler Wireless Setup Smart Thermostat installed wirelessly with receiver Smart Thermostat Smart Thermostat Extension Kit ...

Page 15: ...ng 2 Test the system 3 Hand over the registration card to the customer No Extension Kit Extension Kit present Select Relay R01 or R02 R01 for fully pumped systems R02 for gravity fed systems 2 MIN 2 MIN Configuration download active after saving Installer Menu up to 2 min ...

Page 16: ...Get expert advice on the tado installer hotline 020 3893 2159 or at tado com installers 102022_E ...

Reviews: