9.1 Malfunctions
Error Cause
Elimination
System does not weld. No
spark formation.
System is not switched on.
Switch system on. LED "Ready" must light up. Digital display lights up.
Welding points and/or earth connection points at the workpiece are not
blank. LED display "Stud on Workpiece" does not light up.
Prepare workpiece or studs accordingly. Grind contact points.
Welding cable or control cable is not connected properly or is damaged.
Connect cable properly or check for damage. Replace if necessary.
Wrong mode is set.
Set stud welder to "OP" mode.
No arc although welding
system is ready for
operation.
Weld studs without ignition tip or centre mark too deep for the ignition tip.
Use weld studs with ignition tip or reduce centre mark.
Stud is too loose in stud chuck.
Press stud chuck together or tighten it.
Control of stud welder or stud welding gun is defective.
Contact SOYER customer service.
Stud thread scorched.
Stud is too loose in stud chuck.
Press stud chuck together or tighten it.
Stud chuck worn.
Replace stud chuck.