5.2
Adjustment of operating modes
5.2.1
Starting the stud welder
After switching on the stud welder, the 8 LED lamps light briefly. The stud welder carries out a self
test.
After the self test has been carried out successfully, the stud welder automatically sets the parameters
which were last set.
5.2.2
Operating modes / parameters
Press the function key "Arrow right" or "Arrow left" to select the parameters. Only the parameter
designation which is flashing on the display can be set by means of the function keys.
Operating mode "OP" (Operation)
This operating state must be set for normal welding operation. When the quality control is switched on,
the stud welder locks if welds are outside the tolerance. It can be reset by pressing the LIFT key or
ENTER key (please refer to the description of the quality control).
Operating mode "LIFT" (Lift Test)
This operation mode enables you to adjust and check the lift of the gun or welding head. For further
information, please also refer to the operating instructions for the welding gun or welding head.
Use the function key “Arrow up" or "Arrow down" to set operation mode "LIFT".
Insert a stud into the welding gun or welding head.
Check the immersion depth of the stud and set it according to the operating instructions of the
welding gun or welding head.
CAUTION
Ensure once again that the operation mode is set to "LIFT" and comply with the safety
instructions in chapter 1.