background image

MODE

M400TP

Open

Test

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Data

Tester Description

Cable Tester Top View

1. MODE button

2. LCD display

3. Detachable Remote 

Symbols Used on LCD Display

3

4

RJ45 Jack

Detachable Remote
Bottom View

- RJ45 Jack

RJ45
Jack

    Data:

   

Appears when testing or toning a network cable.

Pass: 

Indicates proper wiring on cable being tested.

Test : 

 

Indicates cable test is in process. 

    1.

    2.

    Volt! : 

Flashes when the tester is connected to a cable with voltage

          on it. Exposure to voltage can damage the tester. If this warning
           appears, immediately disconnect the cable from the tester.
         : Indicates low battery. When this symbol appears, results
           from the tester may not be reliable and the battery should
           be replaced immediately.

Fail: 

Indicates wiring error on cable being tested. 

    3.

 4.

5.

6.

    

 

Open: 

Appears when one or more pairs are open.

Short:

 Indicates that two or more wires are shorted to each other.

Tone:

 

Appears when the tone generator is activated.

Split:

 Appears when the tester detects the signal is split between

          two or more pairs. 

Miswire: 

Appears when the cable has reversed and crossed connections.

S:

 Appears when the cable being tested has a shield that is

    connected at both ends. The Shield indicator will flash if t

here

    is a short between the shield and any wire within the cable. 

X:

 Appears when the tester detects a properly wired cross over cable.

Wire Map near end:

 The top row of numbers displays the connector

pins on the tester end of the cable in numerical order. These pins are
mapped to the pins shown directly below on the bottom row of numbers.  

Wire Map remote end:

 The bottom row of numbers displays the

corresponding pin numbers on the remote end of the cable. Dash lines
indicate shorted pins. No pin numbers indicate an open pair.  
  

Open

Split

Miswire  s   x

Volt!

Short

Fail

Pass

Test

Tone

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Data

1.

2.

3.

4.

5.

6.

Содержание M400TP

Страница 1: ...5 SW T00LS Toll Free Technical Help L nea de Ayuda T cnica Gratuita Scan for a how to video warranty information and to access our mobile site Escanea para video 04 14 Rev 0 M400TP manual Operating In...

Страница 2: ...LOSED WHEN NOT IN USE STORE THE REMOTE WITH PORT ORIENTED INBOARD this protects the port from debris and physical damage 1 2 General Speci cations Operating Temperature Storage Temperature Humidity Ma...

Страница 3: ...pen Short Indicates that two or more wires are shorted to each other Tone Appears when the tone generator is activated Split Appears when the tester detects the signal is split between two or more pai...

Страница 4: ...nown good patch cable to the RJ45 port on the remote 5 Connect the other end of the patch cable to the wall port or patch panel at the other end of the cable being tested 6 Momentarily press the MODE...

Страница 5: ...irs are split Note The T568A wiring standard is the same as T568B except that T568A swaps the green and orange pairs Either standard will test the same electrically as long as the same standard is use...

Страница 6: ...ed during or after the warranty period set forth above please contact the Customer Service Department at 855 SWTOOLS 855 798 6657 The sender is responsible for all shipping freight insurance and packa...

Страница 7: ...V LNL SVZ W LY VZ JVU YH LZJVTIYVZ KH V MxZPJV 1 2 ZWLJP JHJPVULZ NLULYHSLZ Temperatura de Operaci n Temperatura de Almacenamiento Humedad Voltaje M ximo entre dos pines sin da o Pilas Tipo de cables...

Страница 8: ...m s de los alambres tienen un corto Tone Aparece cuando el generador de tono est activado Split Aparece cuando el comprobador detecta que la se al est dividida entre dos pares o m s Miswire Aparece cu...

Страница 9: ...n bueno al puerto RJ45 en el remoto 5 Conecte el otro lado del cable de interconexi n al puerto en la pared o panel de interconexi n al otro lado del cable bajo prueba 6 Presione el bot n MODE por un...

Страница 10: ...ar de cableado del T568A es el mismo del T568B excepto que el T568A cambia los pares verde y anaranjado Cualquiera de los dos har la misma prueba el ctricamente siempre y cuando se utilice el mismo es...

Страница 11: ...ITADA Y LIMITACI N DE RESPONSABILIDAD EN MEDIDORES Y PROBADORES DE SOUTHWIRE Southwire Company garantiza este producto contra defectos en materiales y mano de obra por dos a os desde de la fecha de co...