Specifications
Specifications
NOTICE
The appliance, when installed, must be electrically grounded and comply with local codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.
Southbend reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer
to corresponding changes, additions, or replacements for previously purchased equipment.
This product is intended for commercial use only, not for household use.
Electricity Supply
The following table lists the electricity supply requirements PER OVEN (double for dual-oven models; triple for
triple-oven models).
Supply
Voltage
Oven Component
Total
kW
3-Phase Loading (kW/phase
)
Nominal Amperes per Line-Wire
Minimum Supply
Wire (AWG) Size
L1-L2
L2-L3
L1-L3
L1
L2
L3
1-Phase
Total
3-
Phase
1-
Phase
480
Heating Elements
7.50
2.50
2.50
2.50
9.0
9.0
9.0
16.0
14
10
Motor & Controls
0.90
0.00
0.00
0.90
2.2
0.0
2.2
2.2
415
Heating Elements
7.50
2.50
2.50
2.50
10.4
10.4
10.4
18.1
12
10
Motor & Controls
0.90
0.00
L1-N
0.90
0.0
0.0
3.8
3.8
380
Heating Elements
7.50
2.50
2.50
2.50
11.4
11.4
11.4
20.0
12
8
Motor & Controls
0.90
0.00
L1-N
0.90
0.0
0.0
4.1
4.1
240
Heating Elements
7.50
2.50
2.50
2.50
18.0
18.0
18.0
31.3
10
8
Motor & Controls
0.90
0.00
0.00
0.90
3.8
0.0
3.8
3.8
220
(50Hz)
Heating Elements
7.50
2.50
2.50
2.50
19.7
19.7
19.7
34.1
10
8
Motor & Controls
0.90
0.00
0.00
0.90
4.1
0.0
4.1
4.1
208
Heating Elements
7.50
2.50
2.50
2.50
21.0
21.0
21.0
36.1
8
8
Motor & Controls
0.90
0.00
0.00
0.90
4.3
0.0
4.3
4.3
An electrical diagram is located on the side of the control panel assembly (see drawing on page 30). Electrical
diagrams can also be found in this manual beginning on page 30.
The electrical connections are made directly to the terminals of the heating-element contactor, which is located
inside the control-panel compartment on the right side of the oven. A circular opening sized for a strain-relief fitting
is located on the back of the oven near the right side (right as seen from the front of the oven, see illustration on
page 15). Models with two or three stacked ovens have a separate electrical connection for each oven.
Use 167°F (75°C) wire for all supply lines.
Ovens are shipped wired for either single-phase or three-phase operation, depending on which was specified on
the factory order. If necessary, an oven can be field-converted to use either single-phase or three-phase power
(see page 27)
.