INSTALLATION & OPERATION MANUAL 1194659-ENGLISH, ELEC, REV 1 (11/21)
PAGE
11
OF 36
TruVection Electric Convection Ovens
FIGURE 6
Step 3: Installation of Restraint (Only for Ovens with Casters)
NOTICE
For an appliance equipped with casters, adequate means must be provided to limit the movement of the appliance
without depending on or transmitting stress to the electrical conduit. The restraining means should be attached to
a frame member on the back of the unit and the appliance should be installed using flexible conduit.
1. Secure the restraining-device bracket (item “B” in the following illustration) to a wall stud located as close as possible
to the appliance connector inlet and outlet connections. Use four #12 screws (items “C”) and plastic anchors (items
“A”) if necessary.
2. Install eye-bolt (item “F”) to a frame member on the rear of the equipment. After checking carefully behind the frame
member for adequate clearance, drill a 1/4” hole through the frame member.
3. Thread hex nut (item “G”) and slide the washer (item “H”) onto the eye-bolt. Insert the eye-bolt through the 1/4” drilled
hole and secure with a washer (item “H”) and nylon lock nut (item “I”).
4. Using the spring-loaded snap hooks, attach the restraining device to the bracket and the eye-bolt.
5. Using the cable clamp (item “D”), adjust the restraining device extended length to prevent over-bending or kinking of
the appliance connector.
Installation