INTRODUCTION
SECTION 1: SELF-GENERATING COUNTER TOP
STEAM JACKETED KETTLES
FUNCTIONING MODE - continued
On all tilting kettles the low water sensing probe is installed at the rear of the kettle jacket and during the
pouring operation, as the kettle is tilted forward, the water within the jacket also flows forward exposing
the heating elements and the low water sensing probe and consequently interrupts power supply to the
heating elements. Additionally, each tilting kettle has installed an interlock switch which will also interrupt
the power supply to the heating elements whenever the kettle is not in its normal upright position, i.e.
tilted.
When the Power Switch is turned ON and the Thermostat Knob dialed, simultaneously Temperature pilot
light will glow and contactors will close to allow power to elements and steam generation will commence
and continue until the water contained in the jacket reaches the thermostatic temperature, manually pre-
selected, at which point the thermostat control will de-energize and open the contactors cutting off power
to elements and Temperature pilot light will go off. When the temperature of the water in the jacket drops
slightly, the cycle will repeat itself thus making it possible to maintain any selected precise cooking mode
temperature.
The temperature required for the cooking process to function adequately must be greater than the boiling
point of the liquid food product, viz. water. Further, the higher the temperature, the greater the steam
pressure attained in the jacket and consequently the quicker the cooking process. For example, steam
pressurized at 30 p.s.i. attains a temperature of 274°F.
It should be noted that since air is an unsuitable media through which heat may be transferred, it has
been removed from the kettle jacket during testing at Crown. The Pressure Gauge should indicate
vacuum pressure in the jacket of approximately 20 - 25 p.s.i. when the kettle is not in operation. The
kettle jacket is intended to function at all times as a completely sealed self contained chamber and it is
especially advisable not to trip the safety relief valve during inoperative periods since this will break the
vacuum seal and allow air to enter the kettle jacket.
Содержание KECT-05F
Страница 1: ...MANUAL FOR SELF GENERATING COUNTER TOP STEAM JACKETED KETTLES SOUTHBEND MODEL KECT 05F KECT 10F ...
Страница 5: ...OPERATING CONTROLS AND INDICATORS SECTION 2 SELF GENERATING COUNTER TOP STEAM JACKETED KETTLES FIG 1 ...
Страница 11: ...PARTS LIST SECTION 7 SELF GENERATING COUNTER TOP STEAM JACKETED KETTLES FIG 2 ...
Страница 13: ...PARTS LIST SECTION 7 SELF GENERATING COUNTER TOP STEAM JACKETED KETTLES FIG 3 ...
Страница 16: ...WIRING DIAGRAMS SECTION 8 MODELS EC 5 EC 6 ...
Страница 17: ...WIRING DIAGRAMS SECTION 8 MODELS EC 5 EC 6 ...
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......