background image

INTRODUCTION 

Section 1:                                               SELF-GENERATING COUNTER TOP 

                                      STEAM JACKETED KETTLES 

DESCRIPTION 

All CROWN electrically powered kettles described and referred to in this manual are 
pressure vessels of a double-wall stainless steel construction forming a sealed 
jacket (chamber) enveloping the tower two thirds of the kettle bowl surface. 

The kettle bowl is the container for the food product which ideally should be of a 
liquid or semi-liquid consistency to achieve complete contact with the bowl surface 
and thus fully absorb the heat transmitted through that surface from the pressurized 
steam generated in the kettle jacket. 

The jacket is intended to function as a self contained sealed chamber with a 
permanent solution of water and anti-freeze sufficient not only to immerse and 
thereby protect replaceable electric heating elements but also provide the steam 
source during the steam generating process. 

The heating elements are thermostatically dial controlled to provide precise 
temperatures throughout the range from slow simmer to rolling boil. 

Each kettle is rigidly suspended on a horizontal shaft which is supported by, and 
allowed to rotate within the console housing thereby making it possible to tilt the 
kettle. 

Removal of the food product occurs when the kettle is tilted and contents are 
directed by the pouring lip into an appropriate container. 

All models are intended for permanent mounting to a counter top or suitable 
stand. 

CAPACITIES 

All EC models are suffixed with either -5, -6, -10 or -20 to indicate the capacity of 
that kettle in U.S. Gallons.  Thus an EC-5 indicates an electric self steam 
generating jacketed counter top kettle with a capacity of 5 gallons (U.S.). 

FUNCTIONING MODE 

All CROWN electrically powered self steam generating kettles consist of a jacket 
containing a permanent solution of water and anti-freeze sufficient to completely 
immerse and protect replaceable electric heating elements.  A low water sensing 
probe, as a protective device, is installed in each kettle jacket which will 
automatically interrupt heating element operation and turn on the WATER REQUIRED 
warning light whenever water level is insufficient to immerse not only the probe but 
also the elements. 

Содержание KECT-05F

Страница 1: ...MANUAL FOR SELF GENERATING COUNTER TOP STEAM JACKETED KETTLES SOUTHBEND MODEL KECT 05F KECT 10F ...

Страница 2: ...ctions be followed carefully SECTION PAGE DESCRIPTION Inside Front Cover Warranty Damages etc 1 2 Introduction Description Capacities Functioning Mode 2 4 Operating Controls and Indicators 3 6 Installation Instructions 4 7 Operating and Cleaning Instructions 5 8 Maintenance 6 9 Service Information 7 10 Parts Lists 8 15 Wiring Diagrams ...

Страница 3: ...hout the range from slow simmer to rolling boil Each kettle is rigidly suspended on a horizontal shaft which is supported by and allowed to rotate within the console housing thereby making it possible to tilt the kettle Removal of the food product occurs when the kettle is tilted and contents are directed by the pouring lip into an appropriate container All models are intended for permanent mounti...

Страница 4: ... energize and open the contactors cutting off power to elements and Temperature pilot light will go off When the temperature of the water in the jacket drops slightly the cycle will repeat itself thus making it possible to maintain any selected precise cooking mode temperature The temperature required for the cooking process to function adequately must be greater than the boiling point of the liqu...

Страница 5: ...OPERATING CONTROLS AND INDICATORS SECTION 2 SELF GENERATING COUNTER TOP STEAM JACKETED KETTLES FIG 1 ...

Страница 6: ...thermostat control setting Item D Water Required pilot light when lit indicates insufficient water in kettle jacket and protective sensing probe has interrupted power supply to controls and heating elements Note that tilting of kettle will activate a similar condition but does not necessarily indicate a low water situation Item E Pressure Gauge indicates vacuum in inches of mercury and pressure in...

Страница 7: ... other equivalent sealant along the complete perimeter edge of the kettle base and reposition kettle on counter e Use 5 16 18 Hex Cap Screws with suitable flat washers to bolt down Screw lengths must be 1 1 4 long plus counter top thickness EC 20 Counter Top Models require an additional 1 2 of bolt length f Wipe off excess sealant g A Control Box with power supply equivalent to Electrical Rating o...

Страница 8: ...ill provide simmer and 7 10 low to rolling boil g Turn both kettle Power Switch and Thermostat Knob OFF when cooking has been completed h Remove food product by ladling out of kettle bowl or by tilting and pouring into a suitable container i Clean immediately to prevent residue from drying and adhering to kettle bowl surface CLEANING PROCEDURE a Turn power supply OFF to kettle b Using a nylon brus...

Страница 9: ...e must be followed a Trip the safety relief valve lever to relieve all pressure from kettle jacket b At exterior rear of kettle jacket remove nut from Air Vent c Insert funnel into Air Vent opening and slowly add the indicated amount of clean water for EC 5 and EC 6 Models add 52 ozs EC 10 Model add 108 ozs EC 20 Model add 144 ozs d Replace Air Vent nut e Follow Air Venting Instructions below f Co...

Страница 10: ...on page 8 If water level is sufficient and kettle refuses to operate then check that Interlock Switch in Console is fully engaged when kettle is in its normally upright position Adjust Retaining Collar if necessary to assure complete contact with switch and if kettle still refuses to operate then check for defective switch and or loose wiring connections Initially when Termostat Knob is dialed and...

Страница 11: ...PARTS LIST SECTION 7 SELF GENERATING COUNTER TOP STEAM JACKETED KETTLES FIG 2 ...

Страница 12: ...ief Valve 50 psi 1 5 8 3092 8 3092 8 3142 Tilt Handle 1 6 2 KB01 2 KB01 2 KB01 Knob for Handle 1 7 4 S101 4 S101 4 S101 Power Switch 1 8 8 3087 8 3087 8 3087 Retaining Collar 1 9 4 M605 4 M605 4 M605 Interlock Switch 1 1 11 C7 1 11C7 1 11C7 Fastening Screws for Item 9 2 10 8 3103 8 3103 8 3103 Element Access Cover 1 n 1 33S2 1 33S2 1 33S2 Access Cover Screws 2 12 8 3028 8 3029 8 3119 Trunnion Box ...

Страница 13: ...PARTS LIST SECTION 7 SELF GENERATING COUNTER TOP STEAM JACKETED KETTLES FIG 3 ...

Страница 14: ... LLP1 Probe 1 10 3 68CC 3 68CC 3 68CC Connector 1 11 8 3148 8 3149 8 3150 Copper Tube 1 12 3 66CB 3 66CB 3 66CB Connector 1 13 1 49CO 1 49CO 1 49CO Nut 2 14 3 PG00 3 PG00 3 P600 Pressure Gauge 1 15 8 3097 8 3097 8 3097 Mounting Plate 1 16 3 T8EC 3 T8EC 3 T8EC Thermostat Bulb Connector 1 17 4 TH05 4 TH05 4 TH05 Thermostat 1 18 4 TK05 4 TK05 4 TK05 Thermostat Knob not shown 1 19 4 TB05 4 TB05 4 TB05...

Страница 15: ...required 220 380 7 5016 not required 240 416 7 5017 not required 380 7 5016 4 T251 416 7 5017 4 T253 480 7 5018 4 T255 MODELS EC 10 EC 20 12 KW Elements VOLTAGE ELEMENT NO TRANSFORMER NO 208 7 5019 not required 230 7 5046 not required 240 7 5021 not required 220 380 7 5020 not required 240 416 7 5021 not required 380 7 5020 4 T251 416 7 5021 4 T253 480 7 5022 4 T255 Require Fuse Part No 4 FU03 and...

Страница 16: ...WIRING DIAGRAMS SECTION 8 MODELS EC 5 EC 6 ...

Страница 17: ...WIRING DIAGRAMS SECTION 8 MODELS EC 5 EC 6 ...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Отзывы: