![Sound Devices PIX 250i Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/sound-devices/pix-250i/pix-250i_user-manual-and-technical-information_1333291054.webp)
PIX 250i User Guide and Technical Information
v. 2.00
Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.
48
Ext
er
nal Contr
ol
OSD Menu
The OSD Menu (On-Screen dispaly) provides quick access via the web browser to the PIX 250i
Timecode/Sync
menu options. Menu settings are displayed and can be edited directly from the web
browser.
Remote Menu
The Remote Menu provides quick access via the web browser to the PIX 250i
Remote Control
menu
options. Menu settings are displayed and can be edited directly from the web browser.
Network Menu
The Network Menu provides quick access via the web browser to the PIX 250i
Network
menu op-
tions. Menu settings are displayed and can be edited directly from the web browser. In this menu the
Ethernet File Transfer
option can be remotely activated. This allows for remote transfer of files from
the PIX 250i.
System Menu
The System Menu provides quick access via the web browser to the PIX 250i
System
menu options.
Menu settings are displayed and can be edited directly from the web browser.
Triggering Recording from External Timecode
The PIX 250i can be configured to start recordings when incoming timecode begins rolling and stop
when it becomes stationary. This is generally referred to as Record Run timecode. The master time-
code device should be setup in this manner. To configure the PIX 250i to follow Record Run com-
mands:
1. Set Setup Menu option
[Remote Control - Rec Start/Stop]
to
Timecode
2. Make sure that the device that is sending timecode is configured to send stationary timecode
while stopped and running timecode while recording.
3. Some cameras do not send the correct timecode in the first few seconds of a recording, or
they send short bursts of timecode causing the PIX 250i to record short unintentional files.
The
[Timecode/Sync - Auto Record Hold Off]
feature is designed to eliminate these issues.
When a hold off value is applied, the PIX 250i will begin capturing the moment timecode
begins rolling but will only go into record if a valid timecode signal is present after the hold
off time has elapsed.
Triggering from external timecode will not cause the PIX 250i to automatically stamp ex-
ternal timecode to recorded files. The timecode stamped to files is determined by the setting
[Timecode/Sync - Timecode Mode]
Triggering Recording from SDI Flag Bits
Start and stop flags embedded in the SDI signal from some cameras can be used to
start and stop recording of the PIX 250i. To enable this feature, set Setup Menu option
[Remote Control - Rec Start/Stop]
to the
SDI Flag
option that refers to the manufacturer of the con-
nected camera.