Malfunctions
16
16
16.1 Malfunctions with error messages
If the controller detects a mal-function,
the red light
fl
ashes and the warning
symbol also appears in the display. If
the error is no longer present, the war-
ning symbol changes to an info symbol
and the red light no longer
fl
ashes.
To obtain more detailed information
on the error, press the key under the
warning or info symbol.
Possible error messages:
Sensor x defective ——————>
Collector alarm
————————>
Night circulation ————————>
Restart
————————————>
Time&date ——————————>
Notes for the specialist:
Means that either the sensor, the
sensor input at the controller or the
connecting cable is/was defective.
(Resistance table on page 5)
Means that the collector has fallen/
fell below the temperature set under
menu 6.3.1.
Means that the solar pump is/was in
operation between 23:00 and 04:00.
(Exception see 11.4)
Means that the controller was restar-
ted, for example due to a power failure.
Check the date&time!
This display appears automatically
after a mains failure because the
time&date have to be checked, and
reset if necessary.
(LED
fl
ashes +
warning symbol)
Do not try to deal with this
yourself.
Consult a specialist in the
event of an error!
Danger