![Sony XCL5005 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/sony/xcl5005/xcl5005_technical-manual_418408009.webp)
Ov
e
rvi
ew
Location and Function of Parts and Operation
9
In the case of non-PoCL support:
Both the 1st pin and 26th pin are
INNER_SHIELD (Ground)
Note
When you operate a camera module by inputting an
external trigger signal via the 26-pin connector, make
sure to input external trigger signals that meet the
following specifications to both the two pins.
Specifications for the External Trigger Signal
Amplitude:
LVDS using a 3.3 volt IC
Connections: Input a TRIG (–) signal to the 9th
pin.
Input a TRIG (+) signal to the 22nd
pin.
Polarity:
Positive
Connecting the cables
Connect the camera cable to the DC IN connector and
the Camera Link cable to the digital interface cable
respectively. If you use a camera module interface board
with support for PoCL, you can operate the camera even
if you do not connect the camera cable to the DC IN
connector. When you connect the Camera Link cable,
turn the two fastening screws on the connector to secure
the cable tightly.
Connect the other end of the camera cable to the DC-
700/700CE and the other end of the Camera Link cable
to the camera module interface board.
Note
When using the camera with a PoCL connection, make
sure you connect a PoCL compatible cable. Connecting
a cable that is not compatible with PoCL (non-PoCL)
may cause a malfunction of the camera or camera
module interface board.
Controlling the camera from the host
device
You can control the camera from host device such as a
computer. The following table shows the control
functions.
You can send a command corresponding to the control
items, with parameters for the desired settings, if
necessary, from the host device to control the camera.
Refer to “Camera Control Commands” on page 39 for
details on how to send a command, the commands, and
their parameters.
Note
Make sure to supply power to the camera module and
confirm that the camera module is operating before
inputting a trigger signal. If you input trigger signal to a
camera module without the power supplied, this may
cause a mulfunction of the camera module.
Trigger signal specifications
Input impedance: Stated in the voltage determined at
more than 10 k ohms
b
a
c
d
e
Digital interface connector
Camera Link cable
Fastening screws
DC IN
connector
Camera cable
Control functions
Description
Operating mode
Normal/Trigger
Shutter speed
Normal
2 to 1/10000 s
Trigger edge
2 to 1/10000 s
Trigger pulse
width
Setting by
trigger pulse
width
Gain
0 to +18 dB
Partial Scan
OFF/ON
Gamma control
OFF/ON (Mode 1 to 7)
External trigger input
26 pin connector/12 pin connector
Video output switch
12 bits/10 bits/8 bits
Swtich output tap
1TAP/2TAP
White balance
(XCL-5005CR only)
PRESET/MANUAL/ONE PUSH
(AUTO)
Switch color output
(XCL-5005CR only)
RAW data/RGB data
Binning (XCL-5005 only)
OFF/ON
Edge detection, Edge
enhancement (XCL-5005
only)
OFF/ON
Binarization (XCL-5005
only)
OFF/ON
3×3 image filtering
(XCL-5005 only)
OFF/ON
DC IN terminal
90%
10%
2 - 5 V
10.0 µs - 2 s
Width
0 - 0.6 V
Rising time
Less than
2.0 µs
Amplitude