![Sony XCL5005 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/sony/xcl5005/xcl5005_technical-manual_418408023.webp)
F
u
nc
ti
ons
4. Camera mode
23
4.2.6.
Trigger partial scan mode
In this mode the partial scan action begins through
synchronization with the external trigger input.
Set T1 in order to comply with the following formula. Refer to the partial scan mode regarding A and B.
T1 > 0.0315 × (A+B) [ms]
1
T1
T2
T3
A
A
1
A
T4
2448 CLK
72 CLK
Trigger partial scan
Example of positive electrode (The horizontal timing is the same as in the normal mode.)
FVAL
LVAL
DVAL
Video
output
TRG
*
There is only one LVAL which is less than 2448 CLK during T4
length in order to adjust the timing. T4 changes by depending
on T1.
*
Trigger mode
T1
T2
Shutter
T3 [ms]
Edge detection mode
See the formula under
this table.
More than 10 µs
OFF
66.86
1/15 s
66.86
1/30 s
33.52
1/100 s
10.18
1/120 s
8.52
1/250 s
4.18
1/500 s
2.18
1/1000 s
1.2
1/2000 s
0.7
1/5000 s
0.4
1/10000 s
0.3
1/7.5 s
Impossible
setting
1/2 s
1 s
2 s