Adjustments
97
(EN)
Adjustments
Magnetic focus “ALL” when the color temperature is 9300K
fH
15.7kHz 24.8kHz 31.5kHz 48.3kHz 64.0kHz 77.1kHz 93.7kHz 106.3kHz
Defocused value (R)
0
0
0
0
0
0
0
0
Defocused value (G)
0
0
0
0
0
0
0
0
Defocused value (B)
+30
+30
+15
+5
0
0
0
0
Magnetic focus “ALL” when the color temperature is 6500K or
5400K
fH
15.7kHz 24.8kHz 31.5kHz 48.3kHz 64.0kHz 77.1kHz 93.7kHz 106.3kHz
Defocused value (R)
–15
–15
–10
0
0
0
0
0
Defocused value (G)
0
0
0
0
0
0
0
0
Defocused value (B)
+30
+30
+15
+5
0
0
0
0
Magnetic focus “ALL” when the color temperature is 3200K
fH
15.7kHz 24.8kHz 31.5kHz 48.3kHz 64.0kHz 77.1kHz 93.7kHz 106.3kHz
Defocused value (R)
+15
+15
+10
0
0
0
0
0
Defocused value (G)
0
0
0
0
0
0
0
0
Defocused value (B)
0
0
0
0
0
0
0
0
4PA
fH
15.7kHz 24.8kHz 31.5kHz 48.3kHz 64.0kHz 77.1kHz 93.7kHz 106.3kHz
Defocused value (R)
0
0
0
0
0
0
0
0
Defocused value (G)
0
0
0
0
0
0
0
0
Defocused value (B)
-30
-30
-30
-30
0
0
0
0
Example
• Color temperature: 9300K, fH: 31.5 kHz
• Blue magnetic focus “ALL” adjustment level: 130
• Blue “4PA” adjustment level: 130
When you give priority to uniformity:
After correcting “4PA” completely, adjust “4PA” to the value arrived at by
adding the value (–30) in the table from the “4PA” adjustment data.
4PA: 130 + (–30) = 100
When you give priority to spot focus:
After adjusting the magnetic focus “ALL” completely, adjust “ALL” to the
value arrived at by subtracting the value (+15) in the table from the “ALL”
adjustment data.
Magnetic focus ALL: 130 – (+15) = 115