2-30
SRX-R320
In the case of the V shift amount is 1/2 screen or more
Flat adjustment
1. Align the V shift with the 1/2 screen position. (Refer to Section 2-3.)
2. Start the SRX Controller. (Refer to Section 2-1-3.)
3. Click the “FUNCTION MEMORY” tab.
The FUNCTION MEMORY window is displayed.
4. Click
the
[SELECT]
button.
n
For creation of the new function memory and for details of the function memory, refer to Section 2-7.
5. Call the FUNCTION MEMORY No. for performing the Flat setting using the
[RECALL]
button.
6. Adjust the image size, focus and image position in the horizontal direction using the zoom and focus
in the “LENS CONTROL” menu. (Refer to “2. FUNCTION MEMORY window” in Section 2-8-3.)
n
Adjust the deviation in the horizontal direction by moving the main unit. (Do not use the H shift.)
7. Adjust the image position in the vertical direction using the adjuster.
8. Fix this unit using the four adjusters and lock it with the nuts.
n
When
the
fi
ne adjustment of height is required, perform adjustment with the V shift. (Do not use the
electric V shift.)
Perform the adjustment with the V shift only in the direction that the shift amount becomes smaller. If
the shift amount exceeds 1/2 screen, the
fi
eld angle adjustment of Scope cannot be performed correctly.
9. Click the “MAINTENANCE” tab.
The MAINTENANCE window is displayed.
10. Adjust the luminance using the required test pattern in the “TEST PATTERN” menu.
11. Click the “FUNCTION MEMORY” tab.
The FUNCTION MEMORY window is displayed.
12. Set the masking in the “MASKING ADJUST” menu.
(Refer to “2.-
MASKING ADJUST” in Section 2-8-3.)
13. Click the
[SELECT]
button.
14. Check the FUNCTION MEMORY No., and then click the
[APPLY]
button. (Memory of Function)
Scope adjustment
1. Start the SRX Controller. (Refer to Section 2-1-3.)
2. Click the “FUNCTION MEMORY” tab.
The FUNCTION MEMORY window is displayed.
3. Click
the
[SELECT]
button.
n
For creation of the new function memory and for details of the function memory, refer to Section 2-7.
4. Call the FUNCTION MEMORY No. for performing the Scope setting using the
[RECALL]
button.
5. Adjust the image size, focus and image position using the zoom, focus in the “LENS CONTROL”
menu and the electric V shift in the “ELECTRIC V SHIFT FUNCTION” menu.
(Refer to “2. FUNCTION MEMORY window” in Section 2-8-3.)
6. Click the “MAINTENANCE” tab.
The MAINTENANCE window is displayed.
7. Adjust the luminance using the required test pattern in the “TEST PATTERN” menu.
8. Click the “FUNCTION MEMORY” tab.
The FUNCTION MEMORY window is displayed.
9. Set the masking in the “MASKING ADJUST” menu. (Refer to “2.-
MASKING ADJUST” in Section 2-8-3.)
10. Click the
[SELECT]
button.
11. Check the FUNCTION MEMORY No., and then click the
[APPLY]
button. (Memory of Function)
Содержание SRX-R320
Страница 1: ...DIGITAL CINEMA PROJECTOR SRX R320 INSTALLATION MANUAL 1st Edition ...
Страница 4: ......
Страница 6: ......
Страница 44: ...1 38 SRX R320 1 14 Dimensions Front Left Exhaust Barycentric position Barycentric position ...
Страница 46: ......
Страница 125: ......
Страница 126: ...Sony Corporation SRX R320 SY E 9 968 659 01 Printed in Japan 2009 10 22 2009 ...