76
Troubleshooting
A
ppen
dix
2201ss
SLOT Mx WRITE PROTECTED
(Mx WP SW ON)
The write-protect switch on the SRMemory card is set to on
and prevents recording to the card in the indicated slot.
2202ss
SLOT Mx FS LOCKED
(Mx FS LOCKED)
The SRMemory card in the indicated slot is locked and
cannot be recorded.
2203ss
SLOT Mx WRITE PROTECTED AND FS
LOCKED (Mx WP AND FS)
The SRMemory card in the indicated slot is write-protected
or locked and cannot be recorded.
2901pp
PORT x VPID MISMATCH BITDEPTH
(P-x VPID B-DP)
The bit length in VPID of the input signal from the indicated
port does not match the system bit length.
2A01pp
PORT x VPID MISMATCH COLORSPACE
(P-x VPID C-SP)
The color space in VPID of the input signal from the
indicated port does not match the system color space.
2B01pp
PORT x VPID MISMATCH LINK INFORMATION
(P-x VPID LINK)
Link data in VPID of the input signal from the specified
connector does not match the data of the connected port.
2C01pp
PORT x X2 ORDER MISMATCH
(P-x X2 ORDER)
The order described in the VPID of the specified port’s
input signal and the system order do not match.
Note
This warning only occurs when x2 mode is selected by Port
Config.
2D01pp
PORT x INVALID SDI DATA
(P-x INVLD SDI)
The SDI input signal data for the displayed port is invalid.
2E01pp
PORT x LEVEL A/B MISMATCH
(P-x LVL-A/B)
Level-A/B of the 3G input signal for the displayed port does
not match.
Note
This warning only occurs when SDI is set to 3G SDI (A) or
3G SDI (B) for Port Config.
470100
RTC BATTERY LOW LEVEL
(RTC BATT LOW)
The lithium battery on the SY-350 board is low on power.
7301pp
PORT x NO REF INFORMATION
(P-x FLD INFO)
Since there is no 30 frames/sec reference data for the 720/
59.94P HD SDI signal input to the indicated port, the signal
cannot be properly locked.
7401pp
PORT x ASYNCHRONOUS VIDEO INPUT
(P-x ASYNC VIN)
The HD SDI input signal at the indicated port is out of
phase by ±5H or more from the reference signal.
E101ss
SLOT Mx FULL, NOT RECORDABLE
(Mx FULL)
Because SRMemory card in the indicated slot has no
space to use for recording, the record operation/command
for the SRMemory card was terminated.
Delete the files on the SRMemory card.
E102ss
SLOT Mx COND3 BAD, NOT RECORDABLE
(Mx COND3 BAD)
Recording is not possible because the space to replace the
bad memory cell is consumed on the SRMemory card in
the indicated slot. The recording operation/command was
terminated.
Replace it with a recordable SRMemory card.
E103ss
SLOT Mx FUNCTION LIMIT
(Mx FUNC LIMIT)
Recording and playback operations for the SRMemory card
inserted in the displayed slot were canceled due to
restrictions on recording and playback.
E105ss
SLOT Mx MAXIMUM FILES, NOT
RECORDABLE
(Mx MAX FILES)
Cancelled SRMemory card recording operations and
commands because the number of files in the SRMemory
card has reached its upper limit.
Delete files in the SRMemory card.
E106ss
SLOT Mx FILE SYSTYEM STUFFED, NOT
RECORDABLE
(Mx FS STUFFED)
Cancelled SRMemory card recording operations and
commands because the SRMemory card in the displayed
slot has reached its file system management limit.
Format the SRMemory card to enable recording.
E107ss
SLOT Mx ALTERNATE UMID GENERATED
(Mx ALT LIMID)
Replaced the UMID of newly-generated files to avoid
duplication of UMID in the SRMemory card in the displayed
slot.
E202pp
PORT x FULL, STOP RECORDING
(P-x FULL STOP)
The SRMemory card in the indicated port is full and
recording was terminated.
Code
1)
Indication
2)
Meaning