5-7
SEL1655G
Preparations of Using a Camera (General E-mount
Interchangeable Lens Digital Camera)
Equipment and Tools
• Camera (General E-mount interchangeable lens digital camera)
• E-Mount Extension Jig
Setting Procedure of Equipment and Tools
1. Attach the A-E mount conversion attachment and the E-Mount
Extension Jig to the A-mount attachment and install them to the
flange back tester as shown below figure.
Note 1:
Confi gure the setting of a camera as follows.
•
Focus Mode: Manual Focus
•
Shake Compensation: OFF
•
Aperture: Open
2. Attach the extension jig (47.00 mm) to the objective lens (10x)
to install it to the flange back tester.
3. Attach the checking lens to the flange back tester as shown in
the following figure, and set the 1000 mm collimator.
1000 mm collimator
Checking lens
Extension Jig (47.00 mm)
A-E mount conversion
attachment
E-Mount Extension Jig
Camera
(General E-mount
interchangeable lens
digital camera)
Camera Table
200×200
FB Tester Stand
4. Turn the focusing ring of the checking lens while observing the
microscope and stop it at the position where the chart image is
in focus.
Preparations of Using a B-L Control Box
Equipment and Tools
• Personal Computer (See Note 1)
• B-L Control Box (Supplied with D-sub 15-pin cable)
• AC cable (Sold on the market)
• RS-232C Cable (D-sub 9-pin (Male with securing screws), D-sub
9-pin (Female with securing screws)) Straight type (Sold on the
market)
• USB to serial cable (D-sub 9-pin (Male)) (Sold on the market)
• Lens adjustment program (BLG-TestProgramV
[][][]
.exe) (See
Note 2)
Note 1:
Personal computer must have the condition that Windows 10
runs normally and USB is connectable.
Note 2:
For adjustment of the SEL1655G, prepare a version 1.1.4.S or
higher of the BLG-TestProgram.
Setting Procedure of Equipment and Tools
1. Attach the A-E mount conversion attachment to the A-mount
attachment and install them to the flange back tester.
2. Attach the extension jig (47.00 mm) to the objective lens (10x)
to install it to the flange back tester.
3. Attach the checking lens to the flange back tester as shown in
the following figure, and set the 1000 mm collimator.
1000 mm collimator
Checking lens
Extension Jig (47.00 mm)
A-E mount conversion
attachment
USB to Serial Cable
D-sub 9-pin: Female
RS-232C Cable
AC Cable
D-sub 9-pin:
Male
B-L Control Box
Personal computer
D-sub 15-pin
cable
Camera Table
200×200
FB Tester Stand
4. Install the BLG-TestProgram in the following procedure.
(1) Download the file “BLG-TestProgramV
[][][]
.zip”, save and
extract it.
(2) Save “BLG-TestProgramV
[][][]
.exe” in an arbitrary folder.
– Continued on next page –
SYS SET
2020/02/04 22:49:28 (GMT+09:00)