ID
Diagnosis
Error value
Type1/2
Note
0x0A
Communication test of camera signal
processor IC
-5: Camera signal processor IC Read/
Write NG
1 ,2
—
Note
When an error is detected in the item, it indicates a possible error in the hardware.
Item2 (Display block diagnosis)
The display block diagnosis tests the following contents.
ID
Diagnosis
Error value
Type1/2
Note
0x01
Communication signal line test of
COPRO (SAD)
-1: Connection error
1, 2
—
0x02
Communication signal line test of
LCD
-1: Connection error
1, 2
—
Item3 (Media block diagnosis)
The media block diagnosis tests the following contents. An error value of "-6" is displayed in some cases with any ID
other than the following IDs, but this is not a problem.
Be sure to turn off the power after Item3 has been executed.
ID
Intended device
Diagnosis
Error value
Type1/2
Note
0x06
USB Device
Register Read/Write
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x08
USB Device
Read/Write
Non-installation "-6" is
always returned.
1
Startup must be com-
pleted
0x09
i.LINK
Register Read/Write
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x0A
i.LINK
Read/Write
Non-installation "-6" is
always returned.
1
Startup must be com-
pleted
0x0B
USB Host
Register Read/Write
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x0D
USB Host
Read/Write
Non-installation "-6" is
always returned.
1
Startup must be com-
pleted
0x11
TK-1(SlotA)
Data Read/Write
Non-installation "-6" is
always returned.
1
Startup must be com-
pleted
0x13
TK-1(SlotB)
Data Read/Write
Non-installation "-6" is
always returned.
1
Startup must be com-
pleted
0x14
PIFC
POWSW
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x15
SPA
POWSW
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x12
Torino
Data Read/Write
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x20
NOR-FlashROM
NOR-Flash ROM data
matching check
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x21
ExpressCard
ExpressCard power
switch ON/OFF control
Non-installation "-6" is
always returned.
1
Startup must be com-
pleted
0x22
(SlotA)
ExpressCard overcur-
rent detection
Non-installation "-6" is
always returned.
1
Startup must be com-
pleted
Continued
PMW-200/PMW-EX280
3-7
Содержание PMW-200
Страница 1: ...SOLID STATE MEMORY CAMCORDER PMW 200 PMW EX280 SERVICE MANUAL 1st Edition Revised 1 ...
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 30: ......
Страница 38: ...3 Install the removed parts by reversing steps of removal PMW 200 PMW EX280 2 8 ...
Страница 82: ......
Страница 96: ......
Страница 122: ...Lens Block Assembly 1301 No Part No SP Description 1301 A 1911 477 A s FRONT ASSEMBLY RP PMW 200 PMW EX280 5 16 ...
Страница 128: ......
Страница 130: ......
Страница 132: ......
Страница 133: ......