3-2.
SERVICE Menu List
3-2-1.
MAINTENANCE Menu
Menu
Submenu
Set value
Description
Test Saw
—
On, Off
Turns On or Off the Test Saw.
Auto BLK Balance
—
Execute, Cancel
Starts the auto black balance adjustment.
Black Shading
Setting
On, Off
Turns On or Off the black shading correction.
Channel Sel
G, B, R
Selects the channel to adjust the black shading.
(The present set values of H Saw, H Para, V Saw,
and V Para for the selected channel are displayed
automatically.)
H Saw
–99 to +99
Adjusts the black shading H Saw correction level.
H Para
–99 to +99
Adjusts the black shading H Para correction level.
V Saw
–99 to +99
Adjusts the black shading V Saw correction level.
V Para
–99 to +99
Adjusts the black shading V Para correction level.
Auto BLK Shad
Execute, Cancel
Starts the auto black shading.
White Shading
Setting
On, Off
Turns On or Off the white shading correction.
Channel Sel
G, B, R
Select the channel to adjust the white shading. (The
present set values of H Saw, H Para, V Saw, and
V Para for the selected channel are displayed au-
tomatically.)
H Saw
–99 to +99
Adjusts the white shading H Saw correction level.
H Para
–99 to +99
Adjusts the white shading H Para correction level.
V Saw
–99 to +99
Adjusts the white shading V Saw correction level.
V Para
–99 to +99
Adjusts the white shading V Para correction level.
Flare
G Flare
–99 to +99
Adjusts the G-ch flare correction level.
B Flare
–99 to +99
Adjusts the B-ch flare correction level.
R Flare
–99 to +99
Adjusts the R-ch flare correction level.
Auto FB Adjust
—
Execute, Cancel
Starts the auto flange back adjustment.
Note
This menu should be carried out with 60i or
50i to enhance the adjustment accuracy.
3-2-2.
RPN CORRECT Menu
Menu
Submenu
Set value
Description
Auto Detection
—
—
Starts automatic detection of RPN.
Channel
—
R, G, B
Specifies color components of pixels to be correc-
ted.
Cursor
—
On, Off
Turns On or Off the correction point indicator cur-
sor.
Cursor H Position
—
1 to 1920
Displays and moves the horizontal address of the
correction point indicator cursor.
Cursor V Position
—
1 to 1080
Displays and moves the vertical address of the cor-
rection point indicator cursor.
Cursor Next
—
—
Moves the correction point indicator cursor to the
next address.
Cursor Prev
—
—
Moves the correction point indicator cursor to the
previous address.
Record
—
Execute, Cancel
Registers the RPN.
Continued
PMW-200/PMW-EX280
3-3
Содержание PMW-200
Страница 1: ...SOLID STATE MEMORY CAMCORDER PMW 200 PMW EX280 SERVICE MANUAL 1st Edition Revised 1 ...
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 30: ......
Страница 38: ...3 Install the removed parts by reversing steps of removal PMW 200 PMW EX280 2 8 ...
Страница 82: ......
Страница 96: ......
Страница 122: ...Lens Block Assembly 1301 No Part No SP Description 1301 A 1911 477 A s FRONT ASSEMBLY RP PMW 200 PMW EX280 5 16 ...
Страница 128: ......
Страница 130: ......
Страница 132: ......
Страница 133: ......