2-2 (E)
PDJ-A640 IM
2-2-2. Moving the Unit on a Forklift
To protect the elevator block from the vibration while
moving, install shipping plates A and B, and move the
shipping rings and fix them. Fix the bin drum with the
rotation stopper screws when moving the machine. (Refer
to Section 3-6. “Removing/Moving the Fixed Parts at
Shipment”.)
n
The eyebolts are designed to secure the Professional Disc
Cart machine.
Do not lift the Professional Disc Cart machine by the
eyebolts.
2-3. Installation Condition
Be sure to secure the following installation conditions for
the safety operation of this system and for maintaining the
stable performance for a long period of time.
Be sure to secure the floor strength of the installation
location to be more than the specified value.
c
Install the PDJ-A640 on the location with sufficient floor
strength. If the PDJ-A640 is installed on the location with
insufficient floor strength, the PDJ-A640 may fall causing
death or serious injury.
2-3-1. Operating Environment
Operating temperature:
+
5
°
C to
+
35
°
C
Storage temperature:
_
20
°
C to
+
55
°
C
Operating humidity:
20% to 90%
(No condensation allowed)
Ceiling height:
350 mm or more above the unit.
Floor flatness:
5 mm or less
Floor strength:
when using the standard adjuster
5 kg/cm
2
or more
2-3-2. Prohibited Locations for Installation
.
Areas where the unit will be exposed do direct sunlight
or any other strong lights
.
Dusty areas
.
Areas subject to vibration
.
Areas with strong electric or magnetic fields
.
Areas near the air outlet of an air conditioner
.
Hot and humid areas
Содержание PDJ-A640
Страница 8: ......
Страница 16: ......
Страница 48: ......
Страница 76: ......
Страница 78: ...Printed in Japan Sony Corporation 2009 10 16 2006 PDJ A640 SY J E 3 992 428 03 ...