75
English
11. Specifications
LH61-3
3 axes
7 digits and minus display, fluorescent character display tube (leading–zero suppression, floating
minus sign system)
•
Magnescale axes : 0.0005 mm, 0.001 mm, 0.005 mm, 0.01 mm and diameter display
(0.00002", 0.00005", 0.0001", 0.0005" and diameter display)
•
GA axes
: 0.005 mm, 0.01 mm and diameter display
(0.0002", 0.0005", 0.001" and diameter display)
•
Digiruler axes
: 0.01 mm, 0.02 mm, 0.05 mm, 0.1 mm and diameter display
(0.0005", 0.001", 0.002", 0.005" and diameter display)
•
Magnescale axes : 60 m/min. (39"/s) (however, 1.8 m/min. during absolute zero point detection)
•
GA axes
: 60 m/min. (39"/s)
•
Digiruler axes
: 300 m/min. (196"/s)
1. Temporary power failure
2. Scale disconnected or scale movement speed faster than the maximum response speed
3. Error in stored data
Resettable at any point on the scale with key switch control or external reset.
Preset with key switch control.
Recall of the data stored by Preset with key switch.
Datum point can be set with key switch. (Max. 10 points)
With the datum point set at any point on the scale, the absolute distance from the datum point can
be displayed while machining in the ABS mode.
When the INC mode display is selected, the displayed value can be halved with key and switch operations.
Combined with a scale with an absolute zero point, the datum point can be relocated by detecting
the absolute zero point.
Combined with touch sensor (option), it performs detection of the datum plane.
1. Hold function
2. Load function
3. Centering function
The value displayed before the power was turned tuned off and the preset value are stored. (Uses
nonvolatile memory)
When the table moves a certain distance, a unit of compensation value is added or subtracted for
linear compensation. 256 different compensation amounts are available.
Compensation amount: Max.
±
600
µ
m/m (
±
0.0006 inch/inch)
Coordinates of machining points can be programmed.
1. Manual programming by key switch
2. Automatic programming by playback
3. Mirror image function when program is executed
Maximum 480 steps with data for 3 axes as one set
Maching point coordinates can be set by entering the diameter and number of divisions of a circle
whose center is the spot position. Angle calculations are performed in 0.001
°
units. However,
0.001
°
units are calculated by linear interpolation using the 0.01
°
unit values.
Compensating ratio : 0.100000 to 9,999999.
The displayed value is converted between inch and millimeter with a switch.
Display data output / basic key operation input / program data input/output
1200/2400/4800/9600 bps switchable, parity (odd/even/none), stop bits (1, 2), data length (7, 8)
100 to 230 VAC
±
10%, 50/60 Hz
Max. 35 V A
•
Operating guaranteed temperature and humidity range:
0 to 40
°
C (32 to 104
°
F) (See P.76 for the humidity)
•
Storage temperature and humidity range : –20 to 60
°
C (–4 to 140
°
F), 20 to 90%RH (non-condensating)
•
Operating guaranteed pressure : 860 to 1060 hPa
•
Installation categories
:
II
•
Pollution degree
: 2
320 mm (W)
×
105 mm (D)
×
153 mm (H)
Approx. 2.5 kg/5.5 Lbs
Power cord .............................................. 1 set
‘
M4
×
16 screws .................................... 2 pcs.
Ground wire ............................................ 1 pc.
Rubber spacers (for USA only) .............. 2 pcs.
Remote reset connector ......................... 1 pc.
Instruction manual .................................. 1 pc.
Dust caps ................................................ 3 pcs.
Model
Item
LH61-2
2 axis
Connectable scale
Display digits
Resolution
Maximum response speed
Alarm display
Reset
Preset
Recall
Datum point memory
ABS/INC conversion
Halving
Absolute zero point detection/
Offset absolute zero point
Touch sensor
Data storage
Machine error compensation
Programming
Number of program steps
Bolt hole circle
Scaling
In/mm conversion
RS232C input/output
Power voltage
Power consumption
Operating environment
Outside dimensions
Mass
Accessories
Advanced functions
Содержание LH61
Страница 8: ......
Страница 78: ...70 English Assembly of the external reset input connector ...
Страница 152: ...144 Deutsch Zusammenstellung des Verbinders zur Eingang des externen Rückstellungssignals ...
Страница 160: ......