59
English
Operating Procedure
Display
Confirming the settings
BH
PRG
REF
X
Y
Starting the communication
Press the Function setting key after the
settings are completed.
Press the Execute key.
BH
PRG
REF
X
Y
Press the Cancel key.
(The communication is simply interrupted,
and the mode does not change. The
program transfer mode is retained.)
BH
PRG
REF
X
Y
Input and output format
For the NF12:
For NORMAL:
Data
Note
※
: Program number, Unit: in/mm, and $$: INC/ABS
The end of input is identified by “END” or “%” (for the NF12).
If output mode is interrupted, “%” will be output in NF12 mode.
BH
PRG
REF
X
Y
BH
PRG
REF
X
Y
L
SET
H
START
LF
%
CR
%
Data
Data
N
O
X
.
※
$$ CR LF
Y
$$ CR LF
Z
$$ CR LF
N
O
E
.
※
CR LF
N
D
Number
Number
Number
Unit
Unit
Unit
Lights up
Lights up
Lights up
(Displayed for approx. 2
seconds)
Lights up
Lights up
Interrupting the communication
Data format error
If the data format is wrong, a format error
will result. Check the data, and start the
communication over again.
Finishing the communication
After finishing the communication, return
from the transfer mode by pressing
the
key (Cancel key).