KV-32XBR400/36XBR400/36XBR400H/38DRC1/38DRC1C
Screen-Corner Convergence
•
Input crosshatch pattern.
1. Affix a permalloy assembly corresponding to the
misconverged areas.
Dynamic Convergence Adjustments
Set dynamic convergence using the following service mode
adjustment data:
CXA 8070 AP
NO. Register
Function
Data Length
Initial Data
1
YBWU
VCA9
0-63
31
2
YBWL
VCA10
0-63
31
3
RSAP
DC-AMP1
0-63
31
4
RUBW
VCA5
0-63
31
5
RLBW
VCA6
0-63
31
6
LSAP
DC-AMP2
0-63
31
7
LUBW
VCA10
0-63
31
8
LLBW
VCA2
0-63
31
1. YBWU (UPPER Y-BOW)
B R
B R
2. YBWL (BOTTOM BOW)
B R
B R
3. RSAP (RIGHT AMP)
R B
4. RUBW (RIGHT SIDE UPPER C-BOW)
B R
5. RLBW (RIGHT SIDE BOTTOM C-BOW)
R B
6. LSAP (LEFT AMP)
B R
7. LUBW (LEFT SIDE UPPER C-BOW)
B R
8. LLBW (LEFT SIDE BOTTOM C-BOW)
B R