– 57 –
KP-FX43M31/M61/M91
KP-FX53M31/M61/M91
RM-998
Original Condition
DRC-MF
: DRC1250
PICTURE MODE : HI-FINE
3D-NR MODE
: OFF
ECO MODE
: OFF
WIDE MODE
: OFF
Category Item Data
50TV 50VIDEO 60TV 60VIDEO
SAJ
00 PIC
25
(HI-Fine)
02 COL
22 (HI-Fine) (53")
1F (HI-Fine) (43")
06 DYC
0
(HI-Fine)
0C GMS
00
(HI-Fine)
0D GMR
00
(HI-Fine)
0E GMG
00
(HI-Fine)
0F GMB
00
(HI-Fine)
14 CLO
07
07
07
07
16 HUO
07
53 : 07
07
53 : 07
43 : 06
43 : 07
19 PIO
(TWIN)=07
13 ABT
53 : 04, 43 : 07
JGL
03 BBT
00
04 LML
00
05 SCO
07
WHB
05 GDR
1F
08 GCT
1A
Measurement Point
A Board CN1100 :
1
pin R100
t
VR
5
pin B100
t
VB
Note : After the adjustment 5-3. Picture Quality Adjustment,
these adjustment parameters must be recovered to the
original condition.
5-1. Picture Quality Adjustment
5-1-1. Preparation
1. Set in the service mode.
2. Set respective items as follows.
Adjustment Condition
DRC-MF
: DRC1250
PICTURE MODE : HI-FINE
3D-NR MODE
: OFF
ECO MODE
: OFF
WIDE MODE
: OFF
Category
Item
Data
SAJ
00
PIC
3F
06
DYC
00
0C
GMS
00
0D
GMR
00
0E
GMG
00
0F
GMB
00
13
ABT
00
14
CLO
07
16
HUO
07
19
PIO
00
JGL
03
BBT
00
04
LML
03
05
SCO
07
WHB
04
RDR
1F
05
GDR
1F
06
BDR
1F
07
RCT
1F
08
GCT
1F
09
BCT
1F
3. Connect the oscilloscope probe to the following point on the
A board.
SECTION 5
ELECTRICAL ADJUSTMENTS